Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1307049.1
Update Date:2017-08-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1307049.1 :   How to Remove and Replace a T5140/T5240 CPU Fan [VCAP]  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun SPARC Enterprise T5140 Server - Version Not Applicable and later
Sun SPARC Enterprise T5240 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a T5140/T5240 CPU fan

*************************************************************************************
To report errors or request improvements on this procedure, please Add a Comment on Doc ID: 1307049.1
*************************************************************************************

Solution



DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED

No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 60 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

N/A (CPU Fan Modules are hot-swappable)

WHAT ACTIONS ARE REQUIRED:

 

A) Remove a Fan Module

1. Extend the server to the maintenance position.

2. Lift the latch and open the top cover door.

3. The faulty fan module is identified with a corresponding fault LED.

4. Pull up on the green fan module label until you remove the fan module from the chassis.



B) Install a Fan Module

1. With the top cover door open, install the replacement fan module into the server.

2. Apply firm pressure to fully seat the fan module.

3. Verify that the Fan Fault LED on the replaced fan module is off.

4. Close the top cover door

5. Verify that the system Fan Fault LED, Service Required LEDs, and the individual fan module Fault LED are off.

6. Run the ILOM 'show faulty' command to verify that the fan fault has been cleared.



OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A

 

PARTS NOTE:

Same procedure of replacement this unit both for T5140 and T5240. Just a part model is different with each other.

For more details, refer to https://support.oracle.com/handbook_private/Systems/SE_T5140/components.html#Fan for T5140 and https://support.oracle.com/handbook_private/Systems/SE_T5240/components.html#Fan for T5240.


REFERENCE INFORMATION:http://download.oracle.com/docs/cd/E19712-01/index.html