Solution Type Technical Instruction Sure Solution 1307049.1 : How to Remove and Replace a T5140/T5240 CPU Fan [VCAP]
In this Document
Applies to:Sun SPARC Enterprise T5140 Server - Version Not Applicable and laterSun SPARC Enterprise T5240 Server - Version Not Applicable and later Information in this document applies to any platform. GoalHow to remove and replace a T5140/T5240 CPU fan ************************************************************************************* Solution DISPATCH INSTRUCTIONS WHAT SKILLS ARE REQUIRED REMOVAL/REPLACEMENT INSTRUCTIONS: N/A (CPU Fan Modules are hot-swappable) WHAT ACTIONS ARE REQUIRED:
A) Remove a Fan Module 1. Extend the server to the maintenance position. 2. Lift the latch and open the top cover door. 3. The faulty fan module is identified with a corresponding fault LED. 4. Pull up on the green fan module label until you remove the fan module from the chassis. B) Install a Fan Module 1. With the top cover door open, install the replacement fan module into the server. 2. Apply firm pressure to fully seat the fan module. 3. Verify that the Fan Fault LED on the replaced fan module is off. 4. Close the top cover door 5. Verify that the system Fan Fault LED, Service Required LEDs, and the individual fan module Fault LED are off. 6. Run the ILOM 'show faulty' command to verify that the fan fault has been cleared. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A
PARTS NOTE: Same procedure of replacement this unit both for T5140 and T5240. Just a part model is different with each other. For more details, refer to https://support.oracle.com/handbook_private/Systems/SE_T5140/components.html#Fan for T5140 and https://support.oracle.com/handbook_private/Systems/SE_T5240/components.html#Fan for T5240.
Attachments This solution has no attachment |
||||||||||||||
|