Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1307033.1
Update Date:2018-05-03
Keywords:

Solution Type  Technical Instruction Sure

Solution  1307033.1 :   How to Replace a T5140/T5240 or Netra T5440 Hard Disk:ATR:1309:0  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun SPARC Enterprise T5140 Server - Version All Versions and later
Sun SPARC Enterprise T5240 Server - Version All Versions and later
Sun Netra T5440 Server - Version All Versions and later
Information in this document applies to any platform.
***Checked for relevance on 14-02-2014***

Goal

How to remove and replace a T5140/T5240 HDD SSD

**************************************************************************************
To report errors or request improvements on this procedure, please Add a Comment on Doc ID: 1307033.1
**************************************************************************************

Solution

DISPATCH INSTRUCTIONS

Part NOTE: YOU MUST USE pn 542-0388 for all T3, T5xx0, and T3-1B blade disk replacements (300GB)

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: Disk fault

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Hard drives in SPARC Enterprise T5140/T5240 server are capable of being removed and installed while the server is running. Then operating system should be configured by the customer such that the disk drive is free for replacement. e.g. The disk may be part of Solaris Volume Manager, Veritas Volume Manager, mounted file-system, raw partitions, etc. A data backup may be required to restore data onto a replaced disk depending on situation and customer demand.

NOTE: the "cfgadm" commands in this document (and in the Service manual) are for individual drives that are not part of RAID volumes. When a drive is part of a RAID volume, you do not need to unconfigure it before swapping it with a new drive. When replacing a failed drive in a hardware RAID volume, refer to T5140/T5240 Managing RAID Volumes at: https://docs.oracle.com/cd/E19712-01/E21412-01/z40006f59112.html

NOTE: Refer to Disk Slot Configuration in the Administration guide for the mapping of OS device names to physical hard drive slots and to associate internal disk slot numbers with the logical and physical device names for each hard drive.

4-slot: https://docs.oracle.com/cd/E19910-01/E21500-01/z40001e11389628.html

8-slot:  https://docs.oracle.com/cd/E19910-01/E21500-01/z4001fde1391751.html

16-slot:  https://docs.oracle.com/cd/E19910-01/E21500-01/z4001fde1392179.html


WHAT ACTIONS ARE REQUIRED?:

A) Confirm HDD LED Status: Confirm whether a group of three status LEDs of each HDD, the front and rear panel Service Required LEDs are lit when the system detects a hard drive fault.

B) Remove HDD

1. At the Solaris prompt, type the cfgadm -al command. This will list all drives in the device tree, including drives that are not configured.

2. Type cfgadm -c unconfigure to unconfigure the disk.

3. Wait until the blue Ready-to-Remove LED lights. This LED will help you identify which drive is unconfigured and can be removed.


4. On the drive you plan to remove, push the hard drive release button to open the latch.

C) Install HDD

1. Align the replacement drive to the drive slot.

2. With the latch open, slide the hard drive into its bay until it is fully seated. Then close the latch to secure the drive.

3. At the Solaris prompt, type the cfgadm -al command. This will list all drives in the device tree, including drives that are not configured.

4. Type cfgadm -c configure command to configure the disk.

5. Wait until the blue Ready-to-Remove LED is no longer lit on the drive that you installed.

6. At the Solaris prompt, type the cfgadm -al command to list all drives in the device tree, including any drives that are not configured.

D) As sames as above A), confirm HDD LED Status again

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

Reconfigure disk as previously configured. e.g. part of raid set or mounted file-system or raw partition or other.

PARTS NOTE:  refer to system handbook

Sun SPARC Enterprise T5140

https://support.oracle.com/handbook_private/Systems/SE_T5140/components.html#Disks

Sun SPARC Enterprise T5240

https://support.oracle.com/handbook_private/Systems/SE_T5240/components.html#Disks

Sun Netra T5440

https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#Disks

 

Part NOTE: When replacing PN 540-7869 (300GB), YOU MUST CHANGE THE DISK PART NUMBER TO 542-0388 on all T3, T5xx0, and T3-1B blade disk replacement (300GB).
This note should be copied into Special Instructions for the Field Engineer in ATR task.

 

REFERENCE INFORMATION:
T5140 manual: https://download.oracle.com/docs/cd/E19712-01/
T5240 manual: https://download.oracle.com/docs/cd/E19910-01/

Netra T5440: https://docs.oracle.com/cd/E19874-01/index.html

Detailed SVM instructions can be found at  https://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html.
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions

References

<NOTE:1506521.1> - Unable to Replace a Failed Disk - cfgadm -c unconfigure : Hardware Specific Failure: Failed to Unconfigure
<NOTE:1536918.1> - Replacing a drive on 8-Port 6Gbps SAS-2 RAID HBA / 6Gbps SAS-2 RAID Expansion Module (NIWOT) that has not been explicitly failed by the system
<NOTE:1537188.1> - Replacing a drive on 8-Port SAS ADAPTEC RAID HBA (COUGAR) that has not been explicitly failed by the system
<NOTE:1956972.1> - Disk Replacement (Hot Swap) when controlled by HBA Models SGX-SAS6-R-INT-Z and SG-SAS6-R-INT-Z

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback