Solution Type  Technical Instruction Sure

Solution  1306935.1 :   How to Remove and Replace a CHA - Front End Adapter:ATR:949:4  


Related Items
  • Sun Storage 9985 System
  •  
  • Sun Storage 9990 System
  •  
  • Sun Storage 9970 System
  •  
  • Sun Storage 9990V System
  •  
  • Sun Storage 9910 System
  •  
  • Sun Storage 9960 System
  •  
  • Sun Storage 9985V System
  •  
  • Sun Storage 9980 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Storage 9910 System - Version Not Applicable and later
Sun Storage 9980 System - Version Not Applicable and later
Sun Storage 9985 System - Version Not Applicable and later
Sun Storage 9990 System - Version Not Applicable and later
Sun Storage 9970 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a CHA - Front End Adapter 

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

HDS Product Training on CHA replacement and SVP operation.

TIME ESTIMATE: 20 Minutes

FIELD ENGINEER INSTRUCTIONS


PROBLEM OVERVIEW:
- Processor blocking
- CHKX threshold over

CONFIRM THE FAULT BY CHECKING:

Verify through SIM Log and BY using Maintenance Mode of SVP .

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

It Is very important that the Hosts Multipathing software be verified as working before the procedure is started. The CHA PCB is the hosts interface connection to the frame . When the CHA PCB is off-lined , access to the LDEV will be lost if alternate paths to the LDEV are not configured and working correctly through alternate CHA PCB's .

It is also not recommended to perform this procedure during a period of heavy I/O .

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

- Customer verify that mulitpathing works on Hosts accessing the Frame

- Enter maintenance mode in SVP

- Select failing component and initiate replacement

- Replace CHA

- Continue SVP recovery process

- Complete Sim


CONFIRM THE FIX BY:

Verify through the maintenance mode on the SVP , Verify that the customer has access to CHA ports.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify that the host in use have access to the Ldev through All Paths .

PARTS NOTE:
<special notes regarding parts>

ADDITIONAL COMMENTS:

Replacement procedure is RCH1 for all arrays except 9985 , which uses
RMX1 for MIX PCB in addition to RCH1 .

The documents referenced below can be found on site on the array microcode CD.
9990V - 14acc.pdf page ACC04-30 ===> 07rep.pdf page REP01-290
9985V - 14acc.pdf page ACC04-20 ===> 07rep.pdf page REP01-290
9990 - 14acc.pdf page ACC04-40 ===> 07rep.pdf page REP01-181
9985 - 14acc.pdf page ACC04-20/ACC04-40 ===> 07rep.pdf page REP01-280
9980 - 14acc.pdf page ACC04-20 ===> 07rep.pdf page REP01-160
9970 - 14acc.pdf page ACC05-20 ===> 07rep.pdf page REP01-160
9960 - 14acc.pdf page ACC04-20/ACC05-20 ===> 07rep.pdf page REP01-160
9910 - 14acc.pdf page ACC04-20/ACC05-20 ===> 07rep.pdf page REP01-160


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback