How to Replace System Board for Sun Fire 3800, 4800, 4810, 6800, E4900, and E6900 Systems:ATR:1804:4
Related Items |
- Sun Fire 4810 Server
- Sun Fire 3800 Server
- Sun Fire E6900 Server
- Sun Fire 6800 Server
- Sun Fire 4800 Server
- Sun Fire E4900 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire E6900 Server - Version Not Applicable and later
Sun Fire 4800 Server - Version Not Applicable and later
Sun Fire 4810 Server - Version Not Applicable and later
Sun Fire 6800 Server - Version Not Applicable and later
Sun Fire E4900 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace System Board for Sun Fire 3800, 4800, 4810, 6800, E4900, and E6900 Systems
******************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.oracle.com and put a comment on Doc ID: 1306577.1
******************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES ENGINEER NEED:
ScApp, lom
Task Complexity: 4
Time Estimate: 60 minutes
FIELD ENGINEER INSTRUCTIONS
CAP PROBLEM OVERVIEW:
System Board Failure
WHAT STATE SHOULD SYSTEM BE IN TO BE READY TO PERFORM RESOLUTION ACTIVITY?
Examples use a board location of '#'
1) See if DR can be used; If the board is listed in 'cfgadm -av | grep -i perm' output, you can't use DR.
2a) If able to DR, issue 'cfgadm -c disconnect N0.SB#'
2b) If unable, issue 'init 0' and then 'poweroff sb#' at SC prompt
WHAT ACTION DOES ENGINEER NEED TO TAKE:
You will need to move DIMMs from the 'old' board to the 'new' one (same slots).
1) Perform physical SB replacement per Service Manual
2) poweron SB# at SC prompt
3) showchs -b at SC prompt
4) Reset any 'Suspect' or 'Faulty' components to 'ok' from the Main SC or from the lom prompt:
setchs -s OK -r "SR number" -c <comp>
NOTE: If ScApp 5.20.15 or higher, service mode access IS NO LONGER REQUIRED to execute setchs.
If < 5.20.15, contact service to obtain a Service Mode password or generate one yourself at https://modepass.us.oracle.com
(a backup server is also available from https://modepass-bak.us.oracle.com)
Repeat 'setchs' command until all components are 'ok'.
Verify 'showchs -b' is empty.
5) Verify new board firmware matches existing boards & SC(s) ('showboards -p proms' at SC prompt).
If needed, copy firmware from a like board 'flashupdate -c (source board) (destination board)'
6) Consider running extended POST (On domain issue 'eeprom diag-level=max' or at ok prompt 'setenv diag-level max').
7) If you're replacing a COD (Capacity on Demand) enabled board refer to
Sun Fire[TM] 12K/15K/E20K/E25K/F3800/Fx800/Ex900/ servers: How to replace a COD CPU/memory board (Doc ID 1002102.1)
for the needed step to follow
8a) If able to DR, issue 'cfgadm -c configure N0.SB#' at domain level
8b) If unable to DR, issue 'setkeyswitch -d (domainID) off' followed by 'setkeyswitch -d (domainID) on'.
9) Monitor POST.
* If new errors are detected, collect POST and contact Support.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES CUSTOMER NEED TO TAKE TO RETURN SYSTEM TO AN OPERATIONAL STATE:
Boot system if not already booting.
REFERENCE INFORMATION:
Replacement procedures are documented in the Service Manuals:
* Chapter 8, 3800/48x0/6800 Manual http://download.oracle.com/docs/cd/E19095-01/sf3800.srvr/805-7363-15/805-7363-15.pdf
* Chapter 8, E4900/E6900 Manual http://download.oracle.com/docs/cd/E19095-01/sfe4900.srvr/817-4120-13/817-4120-13.pdf