Asset ID: |
1-71-1306434.1 |
Update Date: | 2018-05-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1306434.1
:
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 GRASP Board [VCAP]
Related Items |
- Sun Fire X4200 M2 Server
- Sun Fire X4100 Server
- Sun Fire X4100 M2 Server
- Sun Fire X4200 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire X4100 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 GRASP Board.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4100, X4100 M2, X4200, X4200 M2 Training
TIME ESTIMATE: 90 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 GRASP Board needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server as described in Powering Off the Server.
2. If the server is in a rack, slide it far enough from the rack so that you can remove the main cover. If you cannot safely view and access the component, remove the server from the rack.
3. Remove the main cover as described in Removing the Main Cover of the Sun Fire X4100/X4100 M2 Server or Removing the Main Cover of the Sun Fire X4200/X4200 M2 Servers.
4. Squeeze the plastic standoff that protrudes through the GRASP board to press the standoff's locking tabs.
5. Raise the corner of the GRASP board until it is clear of the locking tab.
6. Pivot the front edge of the GRASP board upward to disengage it from the rear plastic bracket and to disengage its connector from the motherboard.
7. Installation is the reverse of this procedure.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart the system and have the System Administrator verify functionality of the system.
PARTS NOTE:
None
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19121-01/sf.x4200/index.html
Attachments
This solution has no attachment