Asset ID: |
1-71-1306410.1 |
Update Date: | 2018-05-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1306410.1
:
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Coin Cell Battery
Related Items |
- Sun Fire X4200 Server
- Sun Fire X4200 M2 Server
- Sun Fire X4100 M2 Server
- Sun Fire X4100 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4200 Server - Version Not Applicable and later
Sun Fire X4200 M2 Server - Version Not Applicable and later
Sun Fire X4100 Server - Version Not Applicable and later
Sun Fire X4100 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Coin Cell Battery.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 Coin Cell Battery needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Data backup not required but recommended as a precaution
Orderly shutdown of applications
Shutdown of OS and power down of server
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Ensure standard ESD procedures are followed
1. Power off the server and disconnect (REMOVE) the power cords
2. Remove the main (top) cover|
3. Locate battery (behind PCI slots) and remove by gently pulling the clip away from battery and lifting the battery straight up
4. Insert new battery with positive polarity facing the positive embossed sign on the battery holder
5. Replace main cover
6. Re-connect power cords
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Power on and bring up system. Verify LEDs on front panel
PARTS NOTE:
REFERENCE INFORMATION:
Service Manual. http://download.oracle.com/docs/cd/E19121-01/
Attachments