Solution Type Technical Instruction Sure Solution 1306349.1 : How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Memory DIMM [VCAP]
In this Document
Applies to:Sun Fire X4200 Server - Version All Versions to All Versions [Release All Releases]Sun Fire X4200 M2 Server - Version All Versions to All Versions [Release All Releases] Sun Fire X4100 Server - Version All Versions to All Versions [Release All Releases] Sun Fire X4100 M2 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Memory DIMM. SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED: TIME ESTIMATE: 60 minutes TASK COMPLEXITY: 0 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 Memory DIMM needs replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : -Press down on the cover release button and, using the indent for leverage, slide the main cover toward the rear of the chassis approximately 0.5 inch. 3. Locate the DIMM slot on the motherboard from which you will replace a DIMM, as DIMMs must be installed in pairs you'll also need to replace the companion DIMM to the one being replaced. DIMM 0 and 1 are a pair as are DIMM 2 and 3, position of the DIMMs differ in the x4200 from the x4200M2. -Ensure that the DIMM slot ejectors at each end of the memory socket are fully open (rotated outward) to accept the new DIMM 7. Install the top cover. Attachments This solution has no attachment |
||||||||||||||
|