Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1306302.1
Update Date:2018-05-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1306302.1 :   How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Rear Fan Tray [VCAP]  


Related Items
  • Sun Fire X4100 M2 Server
  •  
  • Sun Fire X4200 M2 Server
  •  
  • Sun Fire X4100 Server
  •  
  • Sun Fire X4200 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4200 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 M2 Server - Version All Versions to Not Applicable [Release All Releases to N/A]
Sun Fire X4200 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Rear Fan Tray.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 Rear Fan Tray needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The part is hot-swappable.  No pre-work is required.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Locate rear fan tray (located above power supplies)
2. Unscrew two spring loaded screws
3. Remove fan tray from system by holding the screws and gently pulling
4. Insert new fan tray by aligning with fan tray rails within chassis and push in firmly
5. Tighten screws

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Validate no errors are seen via SP ssh/web access or IPMItool

PARTS NOTE:
Rear fan tray located above power supplies

REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19121-01/sf.x4200/index.html