Asset ID: |
1-71-1306184.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1306184.1
:
How to Remove and Replace a V480/V490 AC Power Cord:ATR:987:0
Related Items |
- Sun Fire V480 Server
- Sun Fire V490 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Sun Fire V480 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V490 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
******************************************************************************
To report errors or request improvements on this procedure,
please go to https://support.oracle.com and put a comment on Doc ID: 1306184.1
******************************************************************************
How to Remove and Replace a V480/V490 AC Power Cord
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Basic Hardware skills
- TIME ESTIMATE: 10 min
- TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
- PROBLEM OVERVIEW:
Power Cord failed.
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
A data backup is not a prerequisite but is a wise precaution. The customer is not required to perform a system shutdown.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
The Sun Fire V480/V490 server has redundant power supplies each with its own power cord. You can swap one power cord while the other one is still running. For a single power source configuration, the system should be already powered down before replace the bad power cord.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
If the replacement was a hot swap on a redundant configuration, the system should be operational and need no further work.
If the replacement was in a system with a single power source, restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
Refer to the System Handbook for the country specific type of power cord.
REFERENCE INFORMATION:
Service Manual V480 "Servicing Cables"
Service Manual V490 "Servicing Cables"
Attachments
This solution has no attachment