Solution Type
Technical Instruction Sure
Solution
1306127.1
:
How to Remove and Replace an HDS Cable:ATR:944:4
Related Items |
- Sun Storage 9985 System
- Sun Storage 9990 System
- Sun Storage 9970 System
- Sun Storage 9990V System
- Sun Storage 9960 System
- Sun Storage 9910 System
- Sun Storage 9985V System
- Sun Storage 9980 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Storage 9985 System - Version Not Applicable and later
Sun Storage 9960 System - Version Not Applicable and later
Sun Storage 9970 System - Version Not Applicable and later
Sun Storage 9980 System - Version Not Applicable and later
Sun Storage 9990 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace an HDS Cable.
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
SE9910/9960/9970 ST9980/9985/9990 Overview and SVP operation
One drive path is most likely disabled/blocked.
TASK COMPLEXITY: 4
TIME ESTIMATE: 120 minutes
*FIELD ENGINEER INSTRUCTIONS*
PROBLEM OVERVIEW:
Most likely received path blockades on one path of all drives on that loop
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Normal state
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace the indicated FSW cable following the SVP and Maintenance Manual instructions
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION:
Maintenance Manual: Action Code
Maintenance Manual: Replace
FAB 1001288.1, and 1000829.1
References
<NOTE:1000829.1> - Specified SE9990 components now require autodumps to be collected and returned on USB memory devices included with the spare PCBs(printed circuit boards).
<NOTE:1001288.1> - Sun StorEdge 9970 and 9980 DKA or FSW replacement may result in HDD Port blockade.
Attachments
This solution has no attachment