Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1306106.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1306106.1 :   How To Remove and Replace a Sun Fire V210/V240 Server Battery:ATR:762:1  


Related Items
  • Sun Fire V240 Server
  •  
  • Sun Fire V210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire V210 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire V240 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How To Remove and Replace V210/V240 Expired Battery

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
V210/V240 product knowledge/training to be qualified as Oracle service personel.

Time Estimate: 150 minutes

Task Complexity: 1

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:
Real time clock battery dead.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Power down system.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Take ESD precautions and ensure system is powered off.

2. Open back of system cover.

3. Unclip and remove battery from system board.

4. Insert new battery

5. Close back of system cover.

7. Power up system.

8. Set Time Of Date .

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot Operating system and verify Time Of Date . After verifying TOD correct, start applications.

PARTS NOTE:
When replacing battery, use only identical replacement part.

https://support.oracle.com/handbook_partner/Systems/SunFireV240/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV240_R/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV210/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV210_R/components.html

ADDITIONAL COMMENTS:
Sun Fire V210 and V240 Servers Service Manual 819-4207.

http://download.oracle.com/docs/cd/E19088-01/v210.srvr/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.