Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1306104.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1306104.1 :   How To Remove and Replace V210 Lower Interface Board:ATR:861:1  


Related Items
  • Sun Fire V210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire V210 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How To Remove and Replace V210 Lower Interface Board

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

V210 product knowledge/training to be qualified as Oracle service personel.

Time Estimate: 45 minutes

Task Complexity: 1

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:
Failed interface board.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Power down system.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Take appropriate ESD precautions and ensure that system is powered down.

2. Remove cover assembly.

3. Remove all hard drives, noting their positions for reinstallation.

4. Disconnect interface board interconnect cable.

5. Disconnect PDB cable.

On the lower interface board:.

8. Disconnect the system board cable.

9. Disconnect the PSU cable.

10. Disconnect system configuration card reader cable.

11. Unscrew the three screws and five standoffs that secure the lower interface boaed to the chassis.

12. Lift board partways from chassis and remove cabel from bezel assembly.

13. Remove lower interface board from chassis.

14. Locate the new lower interface board into the chassis using the screw hole in the corners as guides.

15. Screw the lower interface board into place.

16. Attach bezel, PCB, PSU and system board cables.

17. Attach lower interface board, PDB and system board connection cables.

18. Reinstall disk drives in their respective slots.

19. Reinstall cover assembly.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot Operating system and start applications.

PARTS DETAILS

https://support.oracle.com/handbook_partner/Systems/SunFireV210/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV210_R/components.html

 


REFERENCE INFORMATION:
Service Manual and Admin Guide: http://download.oracle.com/docs/cd/E19088-01/v210.srvr/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback