Asset ID: |
1-71-1306104.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1306104.1
:
How To Remove and Replace V210 Lower Interface Board:ATR:861:1
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire V210 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How To Remove and Replace V210 Lower Interface Board
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
V210 product knowledge/training to be qualified as Oracle service personel.
Time Estimate: 45 minutes
Task Complexity: 1
*FIELD ENGINEER INSTRUCTIONS*
PROBLEM OVERVIEW:
Failed interface board.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Power down system.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Take appropriate ESD precautions and ensure that system is powered down.
2. Remove cover assembly.
3. Remove all hard drives, noting their positions for reinstallation.
4. Disconnect interface board interconnect cable.
5. Disconnect PDB cable.
On the lower interface board:.
8. Disconnect the system board cable.
9. Disconnect the PSU cable.
10. Disconnect system configuration card reader cable.
11. Unscrew the three screws and five standoffs that secure the lower interface boaed to the chassis.
12. Lift board partways from chassis and remove cabel from bezel assembly.
13. Remove lower interface board from chassis.
14. Locate the new lower interface board into the chassis using the screw hole in the corners as guides.
15. Screw the lower interface board into place.
16. Attach bezel, PCB, PSU and system board cables.
17. Attach lower interface board, PDB and system board connection cables.
18. Reinstall disk drives in their respective slots.
19. Reinstall cover assembly.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot Operating system and start applications.
PARTS DETAILS
https://support.oracle.com/handbook_partner/Systems/SunFireV210/components.html
https://support.oracle.com/handbook_partner/Systems/SunFireV210_R/components.html
REFERENCE INFORMATION:
Service Manual and Admin Guide: http://download.oracle.com/docs/cd/E19088-01/v210.srvr/index.html
Attachments
This solution has no attachment