Asset ID: |
1-71-1306084.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1306084.1
:
How To Remove and Replace V210/V240 Graphics Card:ATR:758:0
Related Items |
- Sun Fire V240 Server
- Sun Fire V210 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V240 Server - Version Not Applicable and later
Sun Fire V210 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How To Remove and Replace V210/V240 Graphics Card
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 40 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: Faulty PCI card.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTIONS ARE REQUIRED:
Follow standard ESD procedures to avoid Electrostatic Discharge
1. Ensure the server is powered off.
2. Ensure that the server is properly grounded.
3. Open the back section of the server.
4. Unscrew the PCI lockdown screw on the back of the server.
5. Remove the PCI lockdown bracket on the inside of the server.
6. Slide the PCI card support clear of the PCI card.
7. Pull up on the riser card support handle to slide it to another position.
8. Disconnect and remove the PCI card.
9. Locate the replacement PCI card in the appropriate slot and press it firmly into the connector.
10. Locate the PCI card support so that it supports the back of the card.
11. Attach the PCI lockdown bracket and tighten the PCI lockdown screw.
12. Refit cover.
13. If system is degraded after repair seek assistance
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
Bring system back up to a functioning state.
PARTS NOTE:
Sun Fire V240
https://support.oracle.com/handbook_private/Systems/SunFireV240/components.html#Graphics
Sun Fire V240 (post July 2006)
https://support.oracle.com/handbook_private/Systems/SunFireV240_R/components.html#Graphics
Sun Fire V210
https://support.oracle.com/handbook_private/Systems/SunFireV210/components.html#Graphics
Sun Fire V210 (post July 2006)
https://support.oracle.com/handbook_private/Systems/SunFireV210_R/components.html#Graphics
ADDITIONAL COMMENTS:
Refer to Service Manual and Admin Guide http://download.oracle.com/docs/cd/E19088-01/
Attachments