Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1305980.1
Update Date:2018-05-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1305980.1 :   How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Fan Module [VCAP]  


Related Items
  • Sun Fire X4200 M2 Server
  •  
  • Sun Fire X4100 Server
  •  
  • Sun Fire X4200 Server
  •  
  • Sun Fire X4100 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4200 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 M2 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Fan Module.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 Fan Module needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

This component is a hot-swappable CRU

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Open the door to the fan bay and identify the defective fan module.

-Fan module LED lit: The fan module is faulty and should be replaced.
-Fan module LED off: The fan module is operating properly.

2. While holding the fan bay door open, grasp the faulty fan module by its plastic strap and lift it straight up out of the fan bay.

3. Visibly inspect the remaining fans and all air openings for dirt, and advise customer if cleaning is necessary.

4. Installation is the reverse of this procedure.

Caution - When you open the fan bay door, be careful to hold it open with one hand so that it does not spring shut and injure your fingers. Do not hold the fan bay door open for more than 60 seconds while the server is running to avoid overheating the server

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

None