Goal
Solution


Applies to:

Sun Fire X4200 M2 Server - Version Not Applicable and later
Sun Fire X4100 Server - Version Not Applicable and later
Sun Fire X4200 Server - Version Not Applicable and later
Sun Fire X4100 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 Fan Board.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 Fan Board needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server as described in Powering Off the Server.

2. If the server is in a rack, slide it far enough from the rack so that you can open the fan bay door. If you cannot safely view and access the component, remove the server from the rack.

3. Open the fan bay door and hold it open. See Opening the Fan Bay Door and Removing a Fan Module.

4. Remove the three fan modules that are connected to the fan connector board you are replacing. Grasp each fan module by its plastic strap and lift it straight up out of the fan bay.

5. Visibly inspect the remaining fans and all air openings for dirt, and clean if necessary.

6. Unfasten the single screw that secures the fan connector board to the chassis.

7. Slide the fan connector board toward the center of the chassis to disconnect it from the front I/O board and to release it from the two locating tabs on the chassis.

8. Lift the board straight up to remove it from the system.

9. Installation is the reverse of this procedure.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.

PARTS NOTE:
Nil

REFERENCE INFORMATION:

Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Service Manual and Diagnostics Guide
http://download.oracle.com/docs/cd/E19121-01/



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback