How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 HDD [VCAP]
Related Items |
- Sun Fire X4200 M2 Server
- Sun Fire X4100 Server
- Sun Fire X4100 M2 Server
- Sun Fire X4200 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Sun Fire X4100 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 HDD.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 HDD needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
This component is a hot-swappable CRU.
If the HDD is part of a Hardware mirror, no other action then replacing the drive is necessary but data backup is a wise precaution. If the HDD is not part of a Hardware RAID or part of a Software Raid, consult customer on data backup before replacement.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Identify the defective drive
2. Press the button on the face of the drive to release the spring-loaded securing latch
3. Grasp the securing latch and remove the drive from the drive bay
4. Push new drive all the way
5. Push back securing latch until it locks
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
If the HDD was part of a Hardware mirror, no other action is required.
If the HDD was not part of a RAID, the customer might need to restore data.
PARTS NOTE:
N/A
REFERENCE INFORMATION:
Sun Fire X4200 http://download.oracle.com/docs/cd/E19121-01/sf.x4200/index.html
Sun Fire X4200 M2 http://download.oracle.com/docs/cd/E19121-01/sf.x4200m2/index.html
Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions