Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1305961.1
Update Date:2018-05-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1305961.1 :   How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 HDD [VCAP]  


Related Items
  • Sun Fire X4200 M2 Server
  •  
  • Sun Fire X4100 Server
  •  
  • Sun Fire X4100 M2 Server
  •  
  • Sun Fire X4200 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4100 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4100 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 M2 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4200 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 HDD.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 HDD needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

This component is a hot-swappable CRU.
If the HDD is part of a Hardware mirror, no other action then replacing the drive is necessary but data backup is a wise precaution.  If the HDD is not part of a Hardware RAID or part of a Software Raid, consult customer on data backup before replacement.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Identify the defective drive
2. Press the button on the face of the drive to release the spring-loaded securing latch
3. Grasp the securing latch and remove the drive from the drive bay
4. Push new drive all the way
5. Push back securing latch until it locks

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

If the HDD was part of a Hardware mirror, no other action is required.
If the HDD was not part of a RAID, the customer might need to restore data.

PARTS NOTE:

N/A

REFERENCE INFORMATION:
Sun Fire X4200 http://download.oracle.com/docs/cd/E19121-01/sf.x4200/index.html
Sun Fire X4200 M2 http://download.oracle.com/docs/cd/E19121-01/sf.x4200m2/index.html



Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html

See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback