Asset ID: |
1-71-1305903.1 |
Update Date: | 2018-05-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1305903.1
:
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 HBA Card
Related Items |
- Sun Fire X4200 Server
- Sun Fire X4200 M2 Server
- Sun Fire X4100 M2 Server
- Sun Fire X4100 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4200 Server - Version Not Applicable and later
Sun Fire X4200 M2 Server - Version Not Applicable and later
Sun Fire X4100 Server - Version Not Applicable and later
Sun Fire X4100 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 HBA Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 HBA Card needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Data backup not required but recommended as a precaution
Orderly shutdown of applications
Shutdown of OS and power down of server
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Ensure standard ESD procedures are followed
1. Power off the server and disconnect (REMOVE) the power cords
2. Remove the main (top) cover
3. Identify the PCI Slot
4. Identify cable(s), label them and disconnect
6. Unscrew holding screw if gently pull the HBA from its slot.
7. Install replacement HBA card in the slot, press it firmly into the connector and screw it.
8. Re-install main cover
9. Re-connect cable(s) according to labeling in step 4
10. Re-connect power cords
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Bring up system and validate new HBA. Verify functionality of system
Verify if configuration changes (WWN change etc) relative to the SAN Switch or Storage System are required with the replacement of the HBA.
PARTS NOTE:
REFERENCE INFORMATION:
Refer to Host Bus Adapter Installation Guide specific to the Host Bus Adapter in system
* Firmware upgrade may be required (details can be found in Installation Guide)
http://download.oracle.com/docs/cd/E19121-01/
Attachments
This solution has no attachment