Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1305775.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1305775.1 :   How To Remove and Replace a V210 Card Reader:ATR:844:1  


Related Items
  • Sun Fire V210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire V210 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How To Remove and Replace a V210 Card Reader

Solution

DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
V210 product knowledge/training to be qualified as Oracle service personel.

Time Estimate: 30 minutes

Task Complexity: 1

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:
Card Reader failed.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Ensure that the system configuration card is not removed before system is brought down.

Follow standard ESD procedures to avoid Electrostatic Discharge

Replace the part following the steps below, refererence the service manual below:

Remove the defective part:

1.Power off the server.
2.Ensure that the server is properly grounded.
3.Remove the front section of the cover assembly.
4.Remove the system configuration card. Place the system configuration card aside.
5.Disconnect the cable leading to the lower interface board from the configuration card reader
6.Unclip the system configuration card reader

Install the new part:

1.Position the new configuration card reader board by lining up the fixing holes with the clips in the top of the DVD drive enclosure.
2.Press the new reader board firmly onto the clips to secure it in place.
3.Reconnect the system configuration card reader power cable.
4.Install the system configuration card.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:
Refer to the System Handbook.

https://support.oracle.com/handbook_partner/Systems/SunFireV210/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV210_R/components.html

 



REFERENCE INFORMATION:
Service Manual and Administration Guide  http://download.oracle.com/docs/cd/E19088-01/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback