How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 PCI Card
Related Items |
- Sun Fire X4200 Server
- Sun Fire X4200 M2 Server
- Sun Fire X4100 M2 Server
- Sun Fire X4100 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4200 M2 Server - Version Not Applicable and later
Sun Fire X4200 Server - Version Not Applicable and later
Sun Fire X4100 Server - Version Not Applicable and later
Sun Fire X4100 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4100, X4100 M2, X4200, X4200 M2 PCI Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4100, X4100 M2, X4200, X4200 M2 PCI Card needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by customer
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server
2. Disconnect all power cables
3. Disconnect any data cables connected to the PCI Card being serviced
4. Remove the Top Cover
-Press down on the cover release button and, using the indent for leverage, slide the main cover toward the rear of the chassis approximately 0.5 inch
-Grasp the cover by its rear edge and lift it straight up from the chassis
5. Remove the PCI card from the slot
-Working from the rear of the chassis, pivot open the PCI card latch that covers the PCI card's rear connector panel
-Pull the PCI card out of the PCI slot
6. Install new PCI card
-Insert the PCI card into the PCI card slot
-Pivot the PCI card latch closed over the rear connector panel of the PCI card until it locks
7. Install the top cover
8. Connect any data cables you removed to service the PCI card
9. Connect all power cables
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Customer might need to consult the PCI card specific manual for procedure to bring the card into operation
PARTS NOTE:
N/A
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19121-01/