Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1305358.1
Update Date:2017-04-03
Keywords:

Solution Type  Technical Instruction Sure

Solution  1305358.1 :   How to Remove and Replace a VSM VCF Card:ATR:901:4  


Related Items
  • Sun StorageTek VSM4 System
  •  
  • Sun StorageTek VSM System
  •  
  • Sun StorageTek VSM5 System
  •  
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
Sun StorageTek VSM4 System - Version All Versions and later
Sun StorageTek VSM5 System
Information in this document applies to any platform.

Goal

How to Remove and Replace a VSM  VCF Card

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED: Sun Storagetek VSM or V2X, including DOP

TASK COMPLEXITY: 4

TIME ESTIMATE: 120 minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: The VCF card is defective and needs to be replaced

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : All CHPIDs assigned to this VCF card must be varied offline.

WHAT ACTIONS DOES THE ENGINEER NEED TO TAKE:
Using LOP (Local Op Panel):
1. From the main menu, select F10 Log On
2. Enter the CSE password (default is b0022222)
3. Select F7 'Guided FRU Replacement Menu'
4. Select F4 'List Composite Failure'
5. Select appropriate CFE ID and follow the on screen step-by-step instructions for
    replacing the FRU

Using DOP (Detached Op Panel):
1. From the main menu log on with the CSE password (default is b0022222)
2. Select 'Guided FRU Replacement'
3. Select 'List Composite Failure Events (CFE)'
4. Select appropriate CFE ID
5. Select 'GFR Selected FRU' and follow on screen step-by-step instructions to
   replace the FRU

CONFIRM THE FIX BY:
Verify the VCF card is no longer fenced and Subsystem Availability is at 100%

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Vary the CHPIDs back online

PARTS NOTE:

After removing the SFP connector covers off of the new VCF card, please re-insert the connector covers on to the old SFPs to be returned with the card.


REFERENCE INFORMATION:
VTSS for VSM4-VSM4e with DOP - Installation and Service Guide

VTSS for VSM4 FICON - Installation, Operation, and Maintenance Guide