Solution  1305332.1 :   How to Replace a T5120/T5220 Disk Backplane Replacement:ATR:1383:2  


Related Items
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun SPARC Enterprise T5220 Server - Version Not Applicable and later
Sun SPARC Enterprise T5120 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a T5120 Disk Backplane Replacement

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1305332.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T5120/5220 Product Knowledge or Training

TIME ESTIMATE: 60 minutes

Task Complexity: 2

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: Faulty Disk Backplane

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.

Customer should shut the operating system down gracefully (using "init 0"), and after the system has shut down Switch from the system console to the -> prompt by typing the #. (Hash Period) key sequence. At the -> prompt, type the stop /SYS command.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

*** Follow standard ESD procedures to avoid Electrostatic Discharge

1. Disconnect all power cables
2. Remove the Top Cover
-Unlatch the fan module door by pulling the release tabs back to release the door
-Press the top cover release button and slide the top cover to the rear about a 0.5 inch
-Lift up and remove the cover

Removal:

1. Remove the hard drive cage.
2. Remove the No. 1 Phillips screws securing the backplane to the hard drive cage.
- Two screws secure the backplane in the Sun SPARC Enterprise T5120 server.
- Four screws secure the backplane in the Sun SPARC Enterprise T5220 server.

3. Slide the backplane down and off the hard drive cage retention hooks.
4. Place the hard drive backplane on an antistatic mat.

Installation:

1. Slide the backplane under the retention hooks on the hard drive cage.
2. Install the No. 1 Phillips screws that secure the backplane to the hard drive cage.
  - Two screws secure the backplane in the Sun SPARC Enterprise T5120 server.
  - Four screws secure the backplane in the Sun SPARC Enterprise T5220 server.

3. Install the hard drive cage.

4. Install Top Cover.

5. Connect all power cables.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE FE/CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:
T5120:  https://support.oracle.com/handbook_partner/Systems/SE_T5120/components.html

T5220:  https://support.oracle.com/handbook_partner/Systems/SE_T5220/components.html


REFERENCE INFORMATION:
Sun SPARC Enterprise® T5120 and T5220 Servers Service Manual - http://download.oracle.com/docs/cd/E19839-01/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback