Asset ID: |
1-71-1305006.1 |
Update Date: | 2016-01-20 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1305006.1
:
How to Update Firmware for SDLT Drive:ATR:87:2
Related Items |
- Sun Storage SDLT Tape Drive
- Sun StorageTek SL500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Storage SDLT Tape Drive - Version Not Applicable and later
Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Update Firmware for SDLT Drive:ATR:87:2
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Oracle/StorageTek SDLT Tape Products, SL Console
TASK COMPLEXITY: 2
TIME ESTIMATE: 120 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Firmware upgrade needed on SDLT drive. This could be due to known issues resolved with more current code or drive is very down-level on code.
CONFIRM THE FAULT BY CHECKING:
Verify level of firmware in drive via Op Panel, SL Console or Drive Diagnostic Utility as in SCSI/FC Toolbox.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Sys-Admin should offline the library and tape drives before upgrade the firmware.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Contact customer to schedule Firmware upgrade.
Locate and download the appropriate drive microcode binaries for drive model, host OS, and interface.
For DLT tape drives, either SCSI/FC Toolbox or the Quantum SDLT Update tool must be used. SCSI/FC Toolbox is the preferred method. (the process detailed below)
1. Select Unloaded/Offline DLT drive from the Bus Scan screen.
2. Pull down the Tape Command Menu.
3. Click the "DLT Firmware Download" command.
4. A window will pop-up displaying all levels of .FUP code loaded in the STKSTB directory or display
another directory, using browse, where .fup code has been stored.
5. Click the level of code to be downloaded, then click open.
6. The following prompt appears:
Are you sure you want to download code?
Yes / No
Click Yes to continue download.
7. The download starts:
Do not interrupt or power cycle. This process may take up to five minutes.
8. The seconds counter ticks, shows activity and cautions:
"Wait until operation is finished."
9. The download is complete when the message appears:
"Cycle the drive handle mechanism. If you cannot, then power cycle the drive"
OK
"Update Finished."
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Have customer bring the drive online to the OS and software application. Verify functionality by running R/W test and check code level via the Software Application.
REFERENCE INFORMATION:
SCSI/FC ToolBox - Obtaining SCSI/Fibre ToolBox / Magma associated Drivers (Doc ID 1016313.1)
TAPE - Finding the latest version of Firmware for Libraries and Tape Drives (Doc ID 1013549.1)
SCSI Toolbox - Installation of the SCSI/Fibre ToolBox, Magma Box Drivers and HBA Drivers (Doc ID 1016314.1
LINK: Sun StorageTek DLT-S4 and SDLT Tape Drives
Attachments
This solution has no attachment