Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1302132.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1302132.1 :   M8000 M9000 How to Replace a Faulty Switch Backplane:ATR:1865:2  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun SPARC Enterprise M8000 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun SPARC Enterprise M9000-32 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M9000-64 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

CAP PROBLEM OVERVIEW: Faulty M8000 M9000 Switch Backplane
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1302132.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

M8000/M9000 training

DELIVERY REQUIREMENT: As scheduled

TASK COMPLEXITY: 2

Time Estimate: 150 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD SYSTEM BE IN TO BE READY TO PERFORM RESOLUTION ACTIVITY?
Data backup is not a pre-requisite but is a wise precaution.
Customer should conduct an orderly software system shutdown.
Power down system.

WHAT ACTION DOES ENGINEER NEED TO TAKE:

Cold replacement with power down is required

SWBP is located behind IOUs in rear of M8000
SWBP is located behind IOUs in rear of un-expanded M9000
SWBP#0 is located behind IOUs in rear of the base cabinet of the expanded M9000
SWBP#1 is located behind IOUs in rear of expansion cabinet of expanded M9000

1. Customer should perform an orderly shutdown of domains

2. Change mode switch setting on operator panel from Locked to Service

3. From a console that is connected to XSCF, log in and execute poweroff -a command

4. Confirm that power-off processing is completed by confirming that POWER LED (green) on operator panel is off

Note: On a M9000 with an expansion cabinet, base cabinet should be switched off first, then expansion cabinet.

5. Switch off all main line switches for AC section (ACS) in power supply system

6. Remove IOUs

a. Turn knob screws securing upper and lower eject/lock levers 90 to 180 degrees to unlock levers.
b. Unlock eject/lock levers to pull IOU off backplane.
c. While grasping handle at front of IOU, pull IOU out partially until NEAR TO END label comes into view.
d. Raise handle at upper part of IOU.
e. While grasping front and upper handles of IOU, pull it out slowly from slot.

7. Remove SWBP to be replaced.
a. Disconnect 5 (M9000) or 3 (M8000) signal cables and two power cords from BP while unlocking connectors.

Note - Be sure to press both lock release buttons inward and pull connector when removing SAS cables (lock release buttons of connector are yellow).

b. Loosen 2 screws securing SWBP.
c. Pull out SWBP carefully.

8. Place removed SWBP on an antistatic conductive mat.

Installation is reverse of above procedure

Note 1 - Do not forcibly push SWBP in when inserting it.

Note 2 - Connector on left edge of base plate of switch BP is not used for M8000

Note 3 - On M9000 with an expansion cabinet, expansion cabinet should be switched on first, then base cabinet.

9. Switch on all main line switches for AC section (ACS) in power supply system.

10. Confirm that XSCF STANDBY LED (green) on operator panel remains lit. If blinking, wait until it remains lit.

Caution !! When maintenance work is completed, confirm mode switch setting and return switch to Locked.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES CUSTOMER NEED TO TAKE TO RETURN SYSTEM TO OPERATIONAL STATE:

Boot & check for full functionality

Confirm hardware fix by running these commands:
XSCF> showhardconf -M
XSCF> showstatus

PARTS NOTE: None

REFERENCE INFORMATION:

Service Manual. http://download.oracle.com/docs/cd/E19415-01/index.html