Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1301378.1
Update Date:2017-03-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1301378.1 :   How to remove and Replace a 280R Graphics Card:ATR:881:1 [Video]  


Related Items
  • Sun Fire 280R Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun Fire 280R Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

******************************************************************************
To report errors or request improvements on this procedure,
please go to https://mosemp.us.oracle.com and put a comment on Doc ID: 1301378.1
******************************************************************************



OTube How to Remove and Replace A Sun Fire 280R Server Graphics Card

 

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire 280R  Server

- TIME ESTIMATE: 45 min
- TASK COMPLEXITY:   1

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Faulty PCI card.

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
A data backup is not a prerequisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures to avoid Electrostatic Discharge
1. Ensure the server is powered off.
2. Ensure that the server is properly grounded.
3. Remove top cover
4. Identify the PCI Slot
5. If there are Cables to be removed, label the cables and disconnect
6. Pull the PCI card from its slot.
7. Firmly install the replacement PCI card in the appropriate slot, and screw it in place.
8. Refit cover.
9. Plug the Cables back into the right Port.
10. Ensure that system powers on and passes POST diagnostics. If applicable, ask the customer
to verify proper system operation. If some circumstance occurs that results in the system being
in a state that is degraded from that of before the repair, and it cannot be easily remedied,
please contact the support center for further diagnosis.


OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
System administrator needs to verify functionality of system.


PARTS NOTE:
Slot 1 is to the right when viewing the system from the back, Slot 4 is on the left (in the middle of the System board)
/pci@8,600000/"device"@1 -- PCI card (Slot 1 J2301)
/pci@8,700000/"device"@1 -- PCI card (Slot 4 J2601)
/pci@8,700000/"device"@2 -- PCI card (Slot 3 J2501)
/pci@8,700000/"device"@3 -- PCI card (Slot 2 J2401)


REFERENCE INFORMATION:

Service Manual


Attachments
This solution has no attachment