![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1301310.1 : How to Remove and Replace an L180/L700/L1400 Op Panel:ATR:967:2
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun StorageTek L700 Tape Library - Version: Not Applicable and later [Release: N/A and later ]Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L700e Tape Library - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to Remove and Replace an L180/L700/L1400 Op Panel:ATR:967:2There is no display on the operator panel or the panel does not function correctly. ⢠Defective AC PDU ⢠Defective DC power supply ⢠Defective operator panel (MPO card). ⢠Defective cable or connection between MPC/MPCL card to MPO (operator panel) card ⢠Defective MPC/MPCL card SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Trained on Lxxx Oracle/STK Tape Library TASK COMPLEXITY: 2 TIME ESTIMATE: 30 minutes WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Library and drives must be taken offline by the customer. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1. Have the customer place the library and drives offline. 2. Open the right front door 3. Is the PDU breaker on? Yes: Go to step 5. No: Turn on breaker. 4. Does the breaker trip? Yes: Go to "TIP 1000: Power---AC PDU" . (L700/1400 Service Manual, PN 95846, Chap. 3) No: Go to step 5. 5. Is the operator panel lit? Yes: Go to step 6. No: "TIP 2000: Power---DC Power" on page 3-7. (L700/1400 Service Manual, PN 95846, Chap. 3) 6. Open the left front access door and check the hand LEDs. Are they lit? Yes: Go to Step 7. No: Go to "TIP 2000: Power---DC Power". (L700/1400 Service Manual, PN 95846, Chap. 3) 7. Use the panel buttons to enter a test or move to a different screen. Does the panel work? No: Replace in this order, checking for operation after each step: 1. Replace the MPO (operator panel) assembly 2. Replace the cable from the MPC/MPCL card to the operator panel 3. Replace the MPC/MPCL logic card OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Have customer bring the library and drives back on line. PARTS NOTE: REFERENCE INFORMATION: L700/1400 Service Manual, PN 95846, Chap. 3 Attachments This solution has no attachment |
||||||||||||
|