Solution Type Technical Instruction Sure Solution 1301309.1 : How to Remove and Replace an L180/L700/L1400 Power Supply:ATR:966:2
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later ]Sun StorageTek L700 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L700e Tape Library - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to Remove and Replace an L180/L700/L1400 Power Supply:ATR:966:2SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED: Trained on Sun/STK Lxxx Library & Drives FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: Power Failure is detected, but no FSC is displayed TASK COMPLEXITY: 2 TIME ESTIMATE: 90 minutes WHAT STATE SHOULD SYSTEM BE IN TO PERFORM RESOLUTION ACTIVITY? Library & drives must be offline. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: If a defective AC or DC power component, follow the steps below: 1. Is there an AC power problem? Yes: Go to TIP 1000: Power---AC PDU. (L700/L1400 Service Manual, Chap.3, P/N95846) No: Go to Step 3. 2. Have a power problem that may relate to redundant power option? Yes: Go to "TIP 1010: Power---UPS Power" (L700/L1400 Service Manual, Chap.3, P/N95846) No: Go to Step 3. 3. Have a DC power problem? Yes: Go to TIP 2000: Power---DC Power. (L700/L1400 Service Manual, Chap.3, P/N95846) No: Go to step 4. CAUTION: Be sure the operator has placed the library and drives offline before troubleshooting library faults. TIP 1000: Power---AC PDU *Use to troubleshoot AC power problems Note: Be sure to follow safety precautions in"Safety, Fiber Optic & ESD" on page xxviii. 4. Have an operator panel problem? Yes: Go to TIP 3000: Operator Panel. (L700/L1400 Service Manual, Chap.3, P/N95846) No: Go to Step 5. 5. Have a problem where the client system cannot access the library? Yes: Go to TIP 4000: SCSI Interface. (L700/L1400 Service Manual, Chap.3, P/N95846) No: Go to Step 7. 6. Have a tape drive problem? Yes: Go to TIP 5000: Tape Drives. No: Go to step 7. 7. Uncertain, run diagnostic tests on library. Refer to "Diagnostic Tests" in Chapter2, "Firmware Operation." (L700/L1400 Service Manual, Chap.3, P/N95846) If PDU breaker trips it is likely that - Defective AC Power Distribution Unit (PDU) - Defective power cable - Incorrect power source - Defective tape drive 1. Open right front door. 2. Is power cord seated properly Yes: Go to step 3. No: Reset power cord. 3. Open right side door & power off all tape drives. 4. Turn on PDU breaker. Does it trip? Yes: Go to step 5. No: Power on drives, one at a time, to see which drive causes breaker to trip. Replace defective drive. 5. Disconnect power cable from customer receptacle. At male pins on power connector, use volt/ohmmeter (set to ohms) to check between the following male pins on power cable: -1 phase pin to GND = open -2nd phase pin to GND = open -1 phase pin to 2nd phase pin = <1 M?? -GND pin to frame = short Are the measurements correct? Yes: Go to step 9 No: Go to step 6 6. Loosen screw on cable strain relief bracket for AC/DC power supply. 7. Remove power cable from bottom of PDU. 8. Use an ohmmeter to check continuity of all three wires in power cable. Is there continuity? Yes: Go to step 9. No: Replace the cable. 9. Plug power cord back into customer's outlet. Leave library end of cord unplugged. WARNING: Electrocution hazard: Take necessary safety measures when measuring line voltage in next procedure. 10. Switch volt/ohmmeter to AC volts & measure line voltage at cable. Nominal voltage for North America = 100--120 VAC Nominal voltage for international = 200--240 VAC Is line voltage correct? Yes: Go to step 11. No: Notify customer. 11. Place cable into bottom of AC PDU. Move breaker to up position. Does breaker still trip? Yes: Replace AC PDU. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Bring Library and Drives back on line. PARTS NOTE: https://support.us.oracle.com/handbook_internal/STK/L1400/L700_1400_components.html REFERENCE INFORMATION: (L700/L1400, Service Manual, Chap.3, P/N95846) Attachments This solution has no attachment |
||||||||||||
|