How to Upgrade L180/700/1400 Library Firmware:ATR:84:2
Related Items |
- Sun StorageTek L180 Tape Library
- Sun StorageTek L700e Tape Library
- Sun StorageTek L1400 Tape Library
- Sun StorageTek L700 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek L700e Tape Library - Version Not Applicable and later
Sun StorageTek L1400 Tape Library - Version Not Applicable and later
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Upgrade L180/700/1400 Library Firmware:ATR:84:2 (Doc ID 1300460.1)
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Sun/Storagetek Tape Products, SCSI/FC Toolbox
TIME ESTIMATE: 90 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Firmware upgrade needed on L180/L700e/L1400 library
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Obtain the equipment from the customer and vary off-line all of the affected libraries and drives.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Verify library firmware level using Op Panel on library:
-Acquire current level of firmware from the Systems Assurance Center:
https://sac.us.oracle.com/download/index.html
-Upgrade library firmware using code load instructions.
http://artemas.us.oracle.com/StorEdge_Products/AutomatedTapeLibraries/L180_700_1400/MPC_3.18.02/LxxxCodeInstallationInstructions_revA.pdf
-Re-initialize library with new code.
- Confirm LXXXX and all transports are functional.
Verify library firmware level using Op Panel on library.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Customer needs to bring up Library and all transports and confirm functionality.
PARTS NOTE:
Code load instruction available through USR
REFERENCE INFORMATION:
SCSI/FC ToolBox - Obtaining SCSI/Fibre ToolBox or Magma associated Drivers (Doc ID 1016313.1)
SCSI Toolbox - Installation of the SCSI/Fibre ToolBox, Magma Box Drivers and HBA Drivers (Doc ID 1016314.1)
References
<NOTE:1016314.1> - SCSI Toolbox - Installation of the SCSI/Fibre ToolBox, Magma Box Drivers and HBA Drivers
<NOTE:1016313.1> - SCSI/FC ToolBox - Obtaining SCSI/Fibre ToolBox or Magma associated Drivers
Attachments
This solution has no attachment