Solution Type Technical Instruction Sure Solution 1300321.1 : How to Replace an IO Board and System Controller (IB_SSC) for Sun Fire v1280, E2900, Netra 1280 and 1290 Systems:ATR:885:4
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers. Applies to:Sun Fire V1280 Server - Version Not Applicable and laterSun Fire E2900 Server - Version Not Applicable and later Sun Netra 1280 Server - Version Not Applicable and later Sun Netra 1290 Server - Version Not Applicable and later Information in this document applies to any platform. GoalHow to Replace an IO Board and System Controller (IB_SSC) for Sun Fire v1280, E2900, Netra 1280 and 1290 Systems
please go to http://support.us.oracle.com and put a comment on Doc ID: 1300321.1
FixDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED:
TASK COMPLEXITY: 4 TIME ESTIMATE: 120 minutes FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD SYSTEM BE IN TO BE READY TO PERFORM RESOLUTION ACTIVITY? The domain needs to be shut down. 1) On the domain issue “init 0” or you can issue “shutdown” from the lom prompt. 2) Take the system to Standby Mode 3) Detach I/O cables. Make sure to label them for re-attachment. WHAT ACTION DOES ENGINEER NEED TO TAKE: 1a) On Sun Fire E2900/v1280, REMOVE left input air filter. * Please insert "FILTER REMOVED" in the comments section of ATR feedback. 1b) On Netra 1280/1290, the customer needs to order & replace the left input air filter (PN X6806A-Z). * This filter maintenance is the customer's responsibility. * Filters are required to be inspected, cleaned, or replaced every 3-6 months per the Periodic Maintenance instructions in or NOTE: Sun Alert 1021703.1 provides the basis for the filter action. 2) Perform physical replacement of IB_SSC unit. * See Service Manual links below for the process. 3) Re-attach I/O cables as labeled. 4) Power on domain. * Either press "On" switch on top panel or issue “poweron” from the lom prompt. 5) Watch SC POST execute on console and validate if errors are present. * Contact Support if errors persist. 6) Update System Controller (lom) firmware. * Mixed firmware configurations is not supported. * Firmware can be updated using the flashupdate command on the SC or lom -G command from Solaris. * An external FTP or HTTP server is required to update firmware via flashupdate command from SC LOM. See the following doc for details on the procedure:
Firmware Download and update procedure for Sun Fire[TM] v1280, 3800, 4800, 4810, 6800, E2900, E4900, E6900, and Netra 1280, 1290 systems. (Doc ID 1006281.1)
See this doc as reference: Sun Fire[TM] v1280/E2900 and Netra[TM] 1280/1290 server: How to flash firmware with lom -G [Video] (Doc ID 1003856.1)
WHAT ACTION DOES CUSTOMER NEED TO TAKE TO RETURN SYSTEM TO AN OPERATIONAL STATE: Boot system and monitor for any boot process errors. If there are issues with locating boot device, validate that all cables were re-attached properly. REFERENCE INFORMATION: Physical replacement procedures are found in the following Manuals: * Chapter 10 , Sun Fire E2900 Manual (http://download.oracle.com/docs/cd/E19095-01/sfe2900.srvr/817-4054-15/817-4054-15.pdf) * Chapter 5.6, Netra 1290 Manual (http://download.oracle.com/docs/cd/E19102-01/n1290.srvr/819-4373-10/819-4373-10.pdf) Attachments This solution has no attachment |
||||||||||||||
|