Asset ID: |
1-71-1299291.1 |
Update Date: | 2016-04-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1299291.1
:
How to replace a SPARC T3-1 & Netra T3-1 XFP, XAUI Card Optical Single Port:ATR:2565:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
SPARC T3-1 - Version Not Applicable and later
Netra T3-1 - Version Not Applicable and later
Information in this document applies to any platform.
Goal
PCIe/XAUI/XFP Card Replacement
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 30 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
Caution – This procedure involves handling circuit boards that are extremely sensitive to static electricity. Ensure that you follow ESD preventative practices to avoid damaging the circuit boards.
WHAT ACTIONS ARE REQUIRED:
Remove a XFP, PCIe or XAUI Card,
1. Perform the preliminary steps required for cold service procedures.
2. Extend the server to the maintenance position.
3. Remove the top cover.
4. Attach an antistatic wrist strap.
5. Disconnect any cables connected to the card.
Note – If the riser has cards installed in both slots, disconnect all cables connected to both cards.
Tip – Label the cables to ensure proper connection to the replacement card.
5a. (Netra only) Remove the PCI Mezzanine board.
6. Remove the riser that contains the card to be removed.
7. With the riser placed on an antistatic surface, disengage the card from its connector and place it on an antistatic surface.
8. If you are not replacing the XFP, PCIe or XAUI card, install a filler panel in the slot.
Install a XFP, PCIe or XAUI Card,
1. Perform the preliminary steps required for cold service procedures.
2. Locate the proper PCIe/XAUI/XFP slot for the card you are replacing.
3. Remove the PCIe/XAUI/XFP riser.
4. If a PCIe filler panel is installed, remove it.
5. Install the XFP, PCIe or XAUI card into the riser.
6. Reinstall the XFP/PCIe/XAUI riser.
6a. (Netra only) Install the PCI Mezzanine board
7. Connect any data cables required to the PCIe/XAUI/XFP card. Route data cables through the cable management arm.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
SPARC T3-1
https://support.oracle.com/handbook_private/Systems/SPARC_T3_1/components.html#Ethernet
NETRA SPARC T3-1
https://support.oracle.com/handbook_private/Systems/Netra_T3_1/components.html#Ethernet
REFERENCE INFORMATION: SPARC T3-1 Service Manual, p/n E21416 or Netra SPARC T3-1 Service Manual, p/n E20693-xx
Attachments
This solution has no attachment