Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1290538.1
Update Date:2017-06-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1290538.1 :   How to Replace a Faulty M3000 M4000 M5000 Fan Unit/Module  


Related Items
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU Cap

Applies to:

Sun SPARC Enterprise M3000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M4000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M5000 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Sun SPARC Enterprise M3000 / M4000 / M5000 How to Replace a Faulty Fan Unit/Module
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://mosemp.us.oracle.com and put a comment on Doc ID: 1290538.1
********************************************************************************

 

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED?:
Engineer has to complete the OPL system training

TASK COMPLEXITY: 1
TIME ESTIMATE: 15 minutes

FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The fan units are active replacement components. To maintain maximum redundancy only one fan module should be removed at a time.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1) Log in to XSCF and execute the replacefru command. ( Must have fieldeng permissions )
2) Select FAN.
3) Select the number of the faulted FAN.
4) Perform the operation according to the instructions displayed in the maintenance menu.
5) Once the replacement is complete check the status to ensure no further fru's are in degraded or faulted status.

XSCF> showhardconf -M

XSCF> showstatus

6) Restart domains if needed.

OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check for all the domains are up and running fine

PARTS NOTE:
REFERENCE INFORMATION:
Service Manual M3000: http://download.oracle.com/docs/cd/E19867-01/index.html