Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1290180.1
Update Date:2016-01-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1290180.1 :   How To Replace the M3000 Disk Backplane:ATR:2462:1  


Related Items
  • Sun SPARC Enterprise M3000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun SPARC Enterprise M3000 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

CAP PROBLEM OVERVIEW: Replace the disk backplane
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1290180.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Field training in SPARC Enterprise M3000 Server

TASK COMPLEXITY: 1

Time Estimate: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:All the power cords must be disconnected to completely cut the power to the server.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

  1. Power off the server using the poweroff -a command at the XSCF command prompt.  Verify the POWER LED is off, and disconnect the power cords.
  2. Slide the server out from the equipment rack.
  3. Remove the top cover.
  4. Remove the air duct from the server.
Removing the disk backplane

  1. Pull out all the hard disk drives (including HDD filler panels) from the server by several centimeters
  2. Remove the two cables from the rear of the hard disk drive backplane
  3. Remove the cables connected to the CD-RW/DVD-RW drive unit.
  4. Pull the CD-RW/DVD-RW drive unit out by several centimeters.
  5. Loosen the two screws to remove the hard disk drive backplane.
  6. Place the hard disk drive backplane on a conductive mat.
Mounting the disk backplane

  1. Mount the hard disk drive backplane.
  2. Tighten the two screws to secure the hard disk drive backplane.
  3. Secure the two cables to the rear of the hard disk drive backplane.
  4. Mount the hard disk drives.
  5. Mount the CD-RW/DVD-RW drive unit
Reassembling the Server

  1. Attach the air duct.
  2. Attach the top cover.
  3. If the equipment rack is supplied with a Quake-Resistant Options Kit or stabilizer, return to its original position.
  4. Power on the server.
    Connect all the power cords to power outlets.
    Verify that the XSCF STANDBY LED on the operator panel is on.
    Turn the mode switch on the operator panel to the desired mode position.
  5. Confirm hardware fix by running the following commands:
    XSCF> showhardconf -M
    XSCF> showstatus

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Post work required to bring the system back online

PARTS NOTE:

REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19867-01/820-5683-13/820-5683-13.pdf

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback