Solution Type  Technical Instruction Sure

Solution  1272661.1 :   How to Replace a Media Bay for Sun Fire V1280/E2900, Netra 1280/1290 [VCAP]  


Related Items
  • Sun Fire V1280 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire E2900 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Part is a FRU

Applies to:

Sun Fire V1280 Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 1290 Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 1280 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire E2900 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a Media Bay for Sun Fire V1280/E2900, Netra 1280/1290

Solution

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1272661.1
********************************************************************************

PROBLEM OVERVIEW:
Removable Media Module failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown.

This procedure requires the system to be extended out of the system cabinet on its slides. Also, before attempting this procedure, you must extend the system cabinet stabilizer bar.

System must be in Standby mode.

TASK COMPLEXITY: 2

TIME ESTIMATE: 60 minutes

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

*** Follow standard ESD procedures to avoid Electrostatic Discharge

1. Take the system to Standby mode.

2. Remove power by removing the four input power cables, AC0 through AC4

3. Make sure that the leveling feet are extended to the floor.

4. Extend and lock the system cabinet stabilizer bar.

5. Slide the system out of the system cabinet until the locking latches click.

6. Open the front door.

7. Attach a wrist strap. Place a grounded ESD mat close to the system.

8. Open the media bay access door. Loosen the latch screw (FIGURE 6-6). Release the latch and lift the cover.

9. Disconnect the following cables from the IB_SSC assembly: disk drive power cable, SCSI data cable, SCC card reader cable, and DVD-ROM drive data/power
cable.

10. Remove the foam air flow filter in front of the IB fan intake.

11. Locate the convex spring behind the right side of the removable media module. Press it in so it becomes concave.

12. Grasp the metal blade located at the front. Remove the removable media module a short distance from the system so that you can reach the connectors.

13. Remove the removable media module. Make sure the connectors and cables do not catch on anything.

14. Place the removable media module on an ESD mat.

15. Insert the new removable media module partially into the system.

16. Push the removable media module fully into the system until the metal tab engages.

17. Reconnect the disk drive power cable, SCSI data cable, SCC card reader cable, and DVD-ROM drive data/power cable to the IB_SSC assembly.

18. Remove the wrist strap.

19. Slide the system into the system cabinet and secure it.

20. Retract the system cabinet stabilization bar.

21. Reattach the power input cables, AC0 through AC4.

22. Power on the system.

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart the applications