Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1272580.1
Update Date:2017-03-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1272580.1 :   How to Remove and Replace a Failed SunFire V480/V490 PCI Fan Tray:ATR:991:1 [Video]  


Related Items
  • Sun Fire V480 Server
  •  
  • Sun Fire V490 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun Fire V490 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V480 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

******************************************************************************
To report errors or request improvements on this procedure,
please go to https://mosemp.us.oracle.com  and put a comment on Doc ID: 1272580.1
******************************************************************************



OTube How to Remove and Replace a Sun Fire V480/V490 PCI Fan Tray

 

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V480/V490 Server

- TIME ESTIMATE: 25 min
- TASK COMPLEXITY:    1

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Fan Tray 1 failure

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
Do not power on the system without a functioning Fan Tray 1 installed.
Doing so could overheat and seriously damage the system.
If Fan Tray 1 fails, the system Fault LED and FT 1 Fault LED will light.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
*** Follow standard ESD procedures to avoid Electrostatic Discharge

1. Power off the system
2. Slide the system out of the cabinet
3. Remove the PCI access panel
NOTE : Fan Tray 1 does not include fan guards. Serious injury can result if you attempt to remove it while the system is running.
4. Pull the fan tray straight up and out of its bracket on the PCI riser board, and set it aside.
5. Insert the new fan tray into its bracket until the fan tray is firmly seated. Make sure that the fan tray connector is oriented to attach to the corresponding connector on the PCI riser board.


OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Verify the LED is in a good status


PARTS NOTE:
None

REFERENCE INFORMATION:

816-0907 Sun Fire V480 Server Parts Installation and Removal Guide
817-3952-11 Sun Fire V490 Parts Installation and Removal Guide


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback