How to Remove and Replace V480/V490 Internal Cables:ATR:989:1 [Video]
Related Items |
- Sun Fire V480 Server
- Sun Fire V490 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Fire V490 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V480 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
******************************************************************************
To report errors or request improvements on this procedure,
please go to https://mosemp.us.oracle.com and put a comment on Doc ID: 1272571.1
******************************************************************************
How to Remove and Replace a Sun Fire V480/V490 Internal Cables
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V480/V490 Server
- TIME ESTIMATE: 40 minutes
- TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Faulty internal cable
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
The customer should conduct an orderly software system shutdown.
System powered off is required.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
*** Follow standard ESD procedures to avoid Electrostatic Discharge
Check the V480/V490 Service manual to identify the cable connection and routing for :
FC-AL power cable, FC-AL data cable, Removable media assembly cable, System controller switch button cable, Fan Tray cable.
1. Power off the system
2. Slide the system out of the cabinet
3. Remove the PCI access panel
4. Replace the appropriate cable from the cable kit, ensuring that the cable is correctly aligned and seated.
5. Install the PCI access panel
6. Slide the system into the cabinet
7. Power on the system
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Verify the LED status
Restart the applications
PARTS NOTE:
None
REFERENCE INFORMATION:
816-0907 Sun Fire V480 Server Parts Installation and Removal Guide
817-3952-11 Sun Fire V490 Parts Installation and Removal Guide