Asset ID: |
1-71-1272257.1 |
Update Date: | 2017-08-08 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1272257.1
:
Sun Fire V880 - V890 How to Replace a Faulty System SEEPROM [VCAP]
Related Items |
- Sun Fire V890 Server
- Sun Fire V880 Server
- Sun Fire V880z Visualization Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire V890 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880z Visualization Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
Sun Fire V880 - V890 How to Replace a Faulty System SEEPROM
Solution
******************************************************************************
To report errors or request improvements on this procedure,
please go to https://mosemp.us.oracle.com and put a comment on Doc ID: 1272257.1
******************************************************************************
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V880/V890 Server
- TIME ESTIMATE: 15 min
- TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Faulty System SEEPROM
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
This section explains how to remove a functioning System SEEPROM module so that you can install it on a new I/O board, thereby preserving the system's host ID information. If you are replacing a defective System SEEPROM module and want to retain the same host ID and Ethernet address, consult your authorized Oracle services representative or service provider for assistance with programming the new System SEEPROM with the existing host ID and Ethernet address.
A data backup is not a prerequisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
System powered off is required.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removal:
Power Off the System
Open and Remove the Side Door
Avoid Electrostatic Discharge
1.Locate the System SEEPROM module on the I/O board.
2.Pull the SEEPROM module from its socket.
3.Place the SEEPROM module on an antistatic mat.
Installation:
1. Carefully seat the system SEEPROM module into its socket on the I/O board. The socket is keyed to ensure proper orientation of the SEEPROM module.
2. Press evenly and firmly until the SEEPROM module is fully seated in the socket.
3. Close the Side Door
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Power On the System and Initiate a Boot
PARTS NOTE:
REFERENCE INFORMATION:
V880 http://download.oracle.com/docs/cd/E19095-01/sfv880.srvr/index.html
V890 http://download.oracle.com/docs/cd/E19095-01/sfv890.srvr/index.html
Attachments
This solution has no attachment