Sun Fire V880 - V890 IO Fan Tray Failure [VCAP]
Related Items |
- Sun Fire V890 Server
- Sun Fire V880 Server
- Sun Fire V880z Visualization Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire V890 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880z Visualization Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to remove and replace a V890 IO Fan Tray
Solution
******************************************************************************
To report errors or request improvements on this procedure,
please go to https://mosemp.us.oracle.com and put a comment on Doc ID: 1271970.1
******************************************************************************
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V880/V890 Server
- TIME ESTIMATE: 20 min
- TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
I/O Fan Tray failure
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
All fan trays feature a hot-swap capability. You can remove and replace a faulty fan tray without shutting down the operating system or turning off the system power. However, at least one working I/O fan tray must be present in order to provide proper system cooling.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures to avoid Electrostatic Discharge
Note:
Use max post only when searching for IO Controller issues, Fatal Resets, and Unrecoverable Errors(UEs) that Solaris is unable to properly diagnose. If diag-level is set to max at OBP, confirm with customer that if can be moved to the factory default of min.
See: Guidance for POST Diagnostic Level Setting on Sun Fire[TM] 280R, V480, V490, V880, V890 and V880z servers. (Doc ID
1582330.1) for details.
If you are not performing a hot-swap procedure, complete the following task (1-2) :
1. Power Off the system
2. Open and remove the side door
3. Identify the fan tray that you want to remove (The primary I/O fan tray is in slot 3).
4. Loosen the two captive Phillips screws securing the fan tray to the brackets.
5. Slide the fan tray out from the brackets.
Note - During a hot-swap operation, after you remove a fan tray or power supply, wait for an acknowledgement message on the system console before installing a replacement part; otherwise, the environmental monitoring software will not recognize the new device and false error conditions will result.
6. Slide the fan tray into the brackets until the connector on the fan tray is fully seated into its socket. The label on the I/O fan tray indicates the orientation of the fan tray.
7. Tighten the two captive Phillips screws that secure the fan tray to the brackets.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Verify the OS functionality and start the applications.
PARTS NOTE:
None
REFERENCE INFORMATION:
V880 http://download.oracle.com/docs/cd/E19095-01/sfv880.srvr/index.html
V890 http://download.oracle.com/docs/cd/E19095-01/sfv890.srvr/index.html
Attachments