Sun Fire V880/V890 Keyswitch / Power Button / LED Replacement [VCAP]
Related Items |
- Sun Fire V890 Server
- Sun Fire V880 Server
- Sun Fire V880z Visualization Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire V880 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880z Visualization Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V890 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
Sun Fire V880/V890 Keyswitch / Power Button / LED Replacement
Solution
******************************************************************************
To report errors or request improvements on this procedure,
please go to https://mosemp.us.oracle.com and put a comment on Doc ID: 1271949.1
******************************************************************************
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V880/V890 Server
- TIME ESTIMATE: 45 min
- TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Keyswitch/Power Button/Front LED failure
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
The customer should conduct an orderly software system shutdown.
System powered off is required.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
*** Follow standard ESD procedures to avoid Electrostatic Discharge
1. Power Off the system
2. Open and remove the side door
3. Remove the two Phillips screws securing the bezel to the front of the system.
4. Remove the two No. 2 Phillips screws and the three No. 1 Phillips screws securing the system status assembly to the front of the system.
5. Carefully remove the status assembly from the front of the system.
6. Disconnect the system status cable (P31) from the connector on the status assembly.
7. Attach the system status cable (P31) to the connector on the side of the system status assembly.
8. Align the status assembly into position on the front of the system.
9. Close the side door
10. Power On the system
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Just verify the function of the component replaced
PARTS NOTE:
None
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19095-01/sfv880.srvr/index.html
http://download.oracle.com/docs/cd/E19095-01/sfv890.srvr/index.html
Attachments
This solution has no attachment