Solution Type Technical Instruction Sure Solution 1271936.1 : How to replace a Power Supply for Sun Fire V1280, E2900, 3800, 4800, 4810, 6800, E4900, E6900, and Netra 1280, 1290 Systems [VCAP]
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun Fire V1280 Server - Version All Versions to All Versions [Release All Releases]Sun Fire 6800 Server - Version All Versions to All Versions [Release All Releases] Sun Fire E4900 Server - Version All Versions to All Versions [Release All Releases] Sun Fire E6900 Server - Version All Versions to All Versions [Release All Releases] Sun Netra 1290 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to replace a Power Supply for Sun Fire V1280, E2900, 3800, 4800, 4810, 6800, E4900, E6900, and Netra 1280, 1290 Systems Solution******************************************************************************
PROBLEM OVERVIEW: Power Supply Unit (PSU) Failure WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : n/a
TASK COMPLEXITY: 1
TIME ESTIMATE: 60 minutes
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1a) If system is a Sun Fire E2900 or v1280, REMOVE left input air filter.
1b) If system is a Netra 1280 or 1290, the customer is required to order and replace left input air filter as soon as possible (PN X6806A-Z).
1c) If system type is Sun Fire 3800, 4800, 4810, 6800, E4900, or E6900, skip to step 2. In instructions below, examples use a location of "#". This type of FRU is a Hot swappable.
2) From Main SC or lom prompt: SC> poweroff ps#
PS#: powered off
3) Perform physical replacement. PSU can be removed when "ok to remove" LED is lit.
4) After PSU has been inserted, from Main SC or lom prompt: SC> poweron ps#
PS#: powered on
5) If the issue persist after PSU replacement contact Oracle support and ask to follow the steps indicated into
Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 - V1280/E2900 - Netra 1280/1290 : Troubleshooting Power Supply Warnings or Failures (Doc ID 1007049.1)
WHAT ACTION DOES CUSTOMER NEED TO TAKE TO RETURN SYSTEM TO AN OPERATIONAL STATE: n/a
REFERENCE INFORMATION:
The physical replacement procedures for the PSU can be found in the following Systems Service Manuals:
* Chapter 4.1 of the Sun Fire 6800/4810/4800/3800 Systems Service Manual (pdf)
* Chapter 4.1 of the Sun Fire E6900/E4900 Systems Service Manual (pdf)
* Chapter 7.1 of the Sun Fire V1280/Netra 1280 Systems Service Manual (pdf)
* Chapter 8.1 of the Sun Fire E2900 System Service Manual (pdf)
* Chapter 6.4 of the Netra 1290 Server Service Manual (pdf) References<NOTE:778.1> - Troubleshooting Video Issues in MOS<NOTE:1021703.1> - Potential for System Outages Due to Cooling Issues on Sun Fire V1280/E2900, Netra 1280/1290 Attachments This solution has no attachment |
||||||||||||||||
|