Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1271911.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1271911.1 :   How to Replace a Fan Tray for Sun Fire V1280/E2900 and Netra 1280/1290 [VCAP]  


Related Items
  • Sun Fire V1280 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire E2900 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire V1280 Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 1280 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire E2900 Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 1290 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Replace a Fan Tray for Sun Fire V1280/E2900 and Netra 1280/1290

Solution

******************************************************************************
To report errors or request improvements on this procedure,
please go to http://mosemp.us.oracle.com and put a comment on Doc ID: 1271911.1
******************************************************************************

PROBLEM OVERVIEW: Fan Tray Failure

 

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : n/a

 

TASK COMPLEXITY: 1

TIME ESTIMATE: 30 minutes

 

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE:

 

1a) If the system is a Sun Fire E2900 or v1280, REMOVE the left input air filter.

  • These systems are qualified to operate without this filter and Sun Alert 1021703.1 provides the basis for this action.
  • Please insert the comment "FILTER REMOVED" in the comments section of the ATR feedback for this action plan to validate this action was taken.
  • This system should also be operating at least ScApp 5.20.14 (Patch 114527-15); See Sun Alert 1021703.1 for justification.

1b) If system is a Netra 1280 or 1290, the customer is required to order and replace left input air filter as soon as possible (PN X6806A-Z).

 

In the instructions below, examples use a location of "#".

 

2) From the lom:

lom> poweroff ft#

FT#: powered off

 

Remove all power cords

3)  Open the front doors of the system.

4)  Attach a wrist strap. Place a grounded ESD mat close to the system.

5)  Unlatch and disconnect the fan tray power connector

6)  Remove the system indicator board connector retaining clip and disconnect the connector.

7)  Loosen the two captive screws to the fan tray in the following order. There is one captive screw at the top and one at the bottom right side of the fan tray.

        a. Loosen the bottom captive screw.

        b. Loosen the top captive screw while supporting the weight of the fan tray with your other hand.

8)  Pull the tray slightly to the right to disengage the mounting pins.

9)  Remove the tray and place it on an ESD mat.

10) Perform the physical replacement. The FT can be removed if the "ok to remove" LED is lit.

11) Orient the tray so that the mounting pins align with the cutouts in the system chassis on the left side.

12) Gently push the tray into place.

13) Tighten the two captive screws, one at the top and one at the bottom right side. This action secures the fan tray.

14) Connect the fan tray power connector. Lock it by pushing it slightly upwards while pressing the locking clip to the right with a screwdriver.

15) Connect the system indicator board connector to the receptacle at the top of the fan tray. Replace the retaining clip.

16) Remove the wrist strap.

17) Close the front doors to the system.

18) After installing the new FT, from the lom:

Insert all power cords

 

lom> poweron ft#

FT#: powered on

 

 

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: n/a

 

REFERENCE INFORMATION:

 

The physical replacement procedures for the FT can be found in the following Systems Service Manuals:

References

<NOTE:1021703.1> - Potential for System Outages Due to Cooling Issues on Sun Fire V1280/E2900, Netra 1280/1290
<NOTE:778.1> - Troubleshooting Video Issues in MOS

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.