How to Remove and Replace A Sun Fire 280R Server Co-Processor Card
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire 280R Server
- TIME ESTIMATE: 45 min
- TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Faulty Co-Processor card.
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
A data backup is not a prerequisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures to avoid Electrostatic Discharge
1. Ensure the server is powered off.
2. Ensure that the server is properly grounded.
3. Remove top cover
4. Identify the PCI Slot
5. If there are Cables to be removed, label the cables and disconnect
6. Pull the PCI card from its slot.
7. Firmly install the replacement PCI card in the appropriate slot, and screw it in place.
8. Refit cover.
9. Plug the Cables back into the right Port.
10. Ensure that system powers on and passes POST diagnostics. If applicable, ask the customer
to verify proper system operation. If some circumstance occurs that results in the system being
in a state that is degraded from that of before the repair, and it cannot be easily remedied,
please contact the support center for further diagnosis.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
System administrator needs to verify functionality of system.
PARTS NOTE:
Slot 1 is to the right when viewing the system from the back, Slot 4 is on the left (in the middle of the System board)
/pci@8,600000/"device"@1 -- PCI card (Slot 1 J2301)
/pci@8,700000/"device"@1 -- PCI card (Slot 4 J2601)
/pci@8,700000/"device"@2 -- PCI card (Slot 3 J2501)
/pci@8,700000/"device"@3 -- PCI card (Slot 2 J2401)
REFERENCE INFORMATION:
Sun Fire 280R Server Service Manual 806-4807