Asset ID: |
1-71-1271029.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1271029.1
:
How to Remove and Install the Sun Fire V240 PCI Riser Card [VCAP]
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire V240 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Remove and Replace a Sun Fire V240 PCI Riser Card
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://mosemp.us.oracle.com and put a comment on Doc ID: 1271029.1
********************************************************************************
Solution
PROBLEM OVERVIEW:
PCI Riser card failure
TASK COMPLEXITY: 1
TIME ESTIMATE: 60 minutes
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
The system should be powered down.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power to the server is off.
2. Remove the server cover
3. Open the rotating service module
4. Wear an antistatic band to avoid any electorstatic discharge
5. Completely remove the airduct and rear fan assembly
6. Using a No.2 Phillips screwdriver, unscrew the PCI lockdown screw on the back of the server
7. Remove the PCI lockdown bracket on the inside of the server
8. Mark the PCI cards with respective slots while removing
9. Pull up on the handle of the PCI cards support and slide the support clear of the PCI cards
10. Unseat the PCI cards from the connector & lift it out of the server
11. Unsrew the two captive screws which secure the PCI riser card to the system board
12. Pull riser card assembly vertically to detach it from the system board
13. Locate replacement riser card and press it home firmly
14. screw it in place
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Followup the start-up procedure as given by sys-admin & confirm the application running fine.
Booting the server and system has detected the PCI cards
PARTS DETAILS:
https://support.oracle.com/handbook_partner/Systems/SunFireV240/components.html
https://support.oracle.com/handbook_partner/Systems/SunFireV240_R/components.html
REFERENCE INFORMATION:
Refer to Service Manual and Admin Guide:
http://download.oracle.com/docs/cd/E19088-01/v240.srvr/819-4207-10/819-4207-10.pdf
Save
Attachments
This solution has no attachment