Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1271029.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1271029.1 :   How to Remove and Install the Sun Fire V240 PCI Riser Card [VCAP]  


Related Items
  • Sun Fire V240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire V240 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to Remove and Replace a Sun Fire V240 PCI Riser Card

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://mosemp.us.oracle.com and put a comment on Doc ID: 1271029.1
********************************************************************************



 

Solution

PROBLEM OVERVIEW:
PCI Riser card failure

TASK COMPLEXITY: 1

TIME ESTIMATE: 60 minutes

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

The system should be powered down.


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power to the server is off.
2. Remove the server cover
3. Open the rotating service module
4. Wear an antistatic band to avoid any electorstatic discharge
5. Completely remove the airduct and rear fan assembly
6. Using a No.2 Phillips screwdriver, unscrew the PCI lockdown screw on the back of the server
7. Remove the PCI lockdown bracket on the inside of the server
8. Mark the PCI cards with respective slots while removing
9. Pull up on the handle of the PCI cards support and slide the support clear of the PCI cards
10. Unseat the PCI cards from the connector & lift it out of the server
11. Unsrew the two captive screws which secure the PCI riser card to the system board
12. Pull riser card assembly vertically to detach it from the system board
13. Locate replacement riser card and press it home firmly
14. screw it in place 


WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Followup the start-up procedure as given by sys-admin & confirm the application running fine.

Booting the server and system has detected the PCI cards

PARTS DETAILS:

https://support.oracle.com/handbook_partner/Systems/SunFireV240/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV240_R/components.html

 

REFERENCE INFORMATION:
Refer to Service Manual and Admin Guide:
http://download.oracle.com/docs/cd/E19088-01/v240.srvr/819-4207-10/819-4207-10.pdf

Save


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.