Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1211643.1
Update Date:2017-02-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  1211643.1 :   Sun Fire[TM] 3800, 4800, 4810, 6800, E4900, E6900, E2900, V1280, Netra[TM] 1280 or 1290 Servers Daylight Savings Time Update Policy  


Related Items
  • Sun Fire 4810 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-x8x0/Ex900
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  




In this Document
Goal
Fix
 Workaround:
References


Applies to:

Sun Fire E2900 Server - Version Not Applicable and later
Sun Fire 4800 Server - Version Not Applicable and later
Sun Fire 3800 Server - Version Not Applicable and later
Sun Fire 4810 Server - Version Not Applicable and later
Sun Fire 6800 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

This document will clarify the support policy for Daylight Savings Time (DST) for the Midrange platforms listed in this article.

Fix

These Platforms are in End of Life (EOL) status.  In this status, only software defects are being remedied within System Controller Application (ScApp).  DST changes are not software defects and there is also a reasonable workaround to adjust for these time changes.

The Midrange Server system controller was last updated for DST rule changes in System Controller Application (ScApp) 5.20.12.  The System controller firmware is currently updated with DST rules up to Olsen tzdata2008i

Workaround:

The use of GMT offsets is suggested for regions that have changed since Olsen tzdata2008i to maintain proper time on the System controller.  Use the command, 'setdate [-v] -t GMT <+|-> offset-from-GMT', which is documented in the Command Reference Manual to adjust to GMT on the SC as needed.  It is also strongly suggested that Solaris DST patches be applied on the platform domain(s) to keep it's time in sync with any changes to DST throughout the world (Solaris DST updates continue to be made in most versions).  

For a more complete discussion of how the System Controller and Solaris clocks are related see 1004720.1.


There is currently a Change Request (CR) open to track customer who wish to
have this product updated regularly for DST changes.  That CR is CR 6986452.
Any customer wishing to get ScApp upgraded with future DST rules should
be added to that CR.

References


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback