Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1185517.1
Update Date:2016-12-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1185517.1 :   VTL - How to collect Xray using VTL Console GUI  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Value System
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
Goal
Solution
 Background
 Exceptions
 Expectations
 Steps to collect the Xray from VTL Console GUI.
References


Applies to:

Sun StorageTek VTL Prime System - Version 1.0 - Build 1813 to 1.1 - Build 2076 [Release 1.0]
Sun StorageTek VTL Storage Appliance - Version 4.0 - Build 1221 to 4.0 - Build 1221 [Release 4.0]
Sun StorageTek VTL Plus Storage Appliance - Version 1.0 - Build 1323 to 2.0 - Build 1656 [Release 1.0 to 2.0]
Sun StorageTek VTL Value System - Version 1.0 - Build 1323 to 1.0 - Build 1323 [Release 1.0]
Red Hat Enterprise Linux Workstation
Sun 386i Sun/OS
.
***Checked for relevance on 21-06-2011*** (dd-mm-yyyy)


Goal

This document is intended to assist field engineers and customers in retrieving a Sun VTL xray, for aiding in remote support of Sun VTL servers.

Solution

Background

VTL Xray is collected by the field engineer or customer, in order for VTL support engineer to analyze and/or troubleshoot VTL issues. This document has step by step instructions for collecting the Xray with the VTL Console GUI.



Exceptions

In Sun VTL failover configurations, when a node has failed over, user will not be able to use VTL Console to collect Xray from the failed node. The document 1146464.1 explains how to get the Xray from the failed node from command line.

 

Expectations

The customer or the engineer is expected to be familiar with the Oracle-Sun VTL product including VTL Console and should have access to an instance of VTL Console that can connect to the VTL server where the Xray is needed.

 

Steps to collect the Xray from VTL Console GUI.

  1. Login to the VTL Console.
  2. Right click the VTL node which needs the Xray taken.
  3. Select connect.
  4. Login to the VTL node
  5. Right click the VTL node again and Select Xray from the drop down list.
  6. If you wish to direct where the Xray file will be placed Click the button with [...] and select the file location.
    Note: Xray files are placed in the directory structure of the system where the VTL Console is run from.
  7. Select the Take X-ray button.
  8. Once the Xray is collected it can be attached to MOS SR. 

 

For additional assistance on uploading files to Oracle Support, reference document 1547088.2

 