Asset ID: |
1-71-1163795.1 |
Update Date: | 2017-05-19 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1163795.1
:
SL3000 - How to Disable or Configure Less Slots Then Licensed
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Applies to:
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
SL3000 - How to Disable or Configure Less Slots Then Licensed
A Customer has a SL3000 with 900 Slots license but due to in-sufficient backup software license, they want to use only 700 Slots on SL3000.
Solution
This is done at the "Select Active Cells" menu option of the remotely connected SLC.
There you can select zero storage cells or up to the maximum licensed count.
NOTE:
When making any changes to the active cell configuration...
(From the SL3000 user's guide)
With FC-SCSI libraries, whenever you make any of the following changes, the library goes offline temporarily with a Unit Attention condition:
- Activate or de-activate a storage cell
- Add, change, or remove a host connection
- Remove an empty drive slot
Multiple error messages may be generated, and all hosts must issue the appropriate commands to update their library configuration information. See the appropriate tape management software documentation for detailed procedures and commands. In the case of adding or removing drives, the device SCSI numbering is updated as well.
Attachments
This solution has no attachment