Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1098573.1
Update Date:2017-11-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1098573.1 :   T10000 - How to Rebuild the MIR on a T10000 Tape Drive Using VOP, ATR 1098573.1  


Related Items
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Goal
Solution
References


Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
Sun StorageTek T10000A Tape Drive - Version Not Applicable and later
StorageTek T10000C Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to rebuild the MIR on a T10000 tape cartridge using VOP.

Solution

When a T10000 tape cartridge needs to have the MIR rebuilt, use the "Make MIR" utility in VOP on an offline drive.

Refer to [Document: 1014070.1] on where to acquire VOP application.

Use the "Rebuild MIR" utility in the Virtual Op Panel (VOP) application using the following steps.

  1. Connect to a drive using the VOP application ... File -> Connect to Drive
  2. Take the drive offline ... Drive Operations -> Set Offline
  3. Open the MIR rebuild Utility ... Drive Operations -> Format Tape
  4. Run the MIR rebuild Utility ... Select Rebuild MIR and click the Make button
  5. Insert the tape to be rebuilt into the drive

This method will:
1. Index all of the block entries in the MIR.
2. Rebuild the defect table entries in the MIR and RFID.
3. Ensure that there is a match between the RFID and MIR table entries.

This utility will run until it reaches the End of Data marker on the tape.  Depending on how much data is on the tape it could take a few minutes or a few hours.

Notes:
 - If the tape was previously involved in a write perm error it probably will not have an EOD block in which case you will see and A737 error when you try to run the rebuild MIR Utility. In this case it is best to have the customer copy the data off of this tape an onto another tape then certify the tape to ensure there is no physical damage to the media. The "Copy To" tape will have a new MIR when the copy operation completes.



Attachments