Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1021104.1
Update Date:2017-05-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  1021104.1 :   How to verify Sun Storage[TM] Array Tray Type via the User Interface  


Related Items
  • Sun Storage B220 Disk Subsystem
  •  
  • Sun Storage 6180 Array
  •  
  • Sun Storage 6580 Array
  •  
  • Sun Storage Flexline 280 Array
  •  
  • Sun Storage D178 Disk Subsystem
  •  
  • Sun Storage 2540-M2 Array
  •  
  • Sun Storage 6780 Array
  •  
  • Sun Storage D173 Disk Subsystem
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage Flexline 210 Array
  •  
  • Sun Storage B280 Array
  •  
  • Sun Storage D220 Disk Subsystem
  •  
  • Sun Storage Flexline 380 Array
  •  
  • Sun Storage 2530-M2 Array
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage D240 (STK) Array
  •  
  • Sun Storage 6540 Array
  •  
  • Sun Storage Flexline 240 Array
  •  
  • Sun Storage D280 Disk Subsystem
  •  
  • Sun Storage 6130 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: 6130
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
270869


Applies to:

Sun Storage Flexline 280 Array - Version Not Applicable and later
Sun Storage Flexline 380 Array - Version Not Applicable and later
Sun Storage B220 Disk Subsystem - Version Not Applicable and later
Sun Storage 2530-M2 Array - Version Not Applicable and later
Sun Storage 2540-M2 Array - Version Not Applicable and later
All Platforms

Goal

The purpose of this document is to describe how to identify the tray type of a given tray for a  Storage[TM], StorageTek[TM],  or StorEdge[TM], array, using the management interface software Common Array Manager or SANtricity Storage Manager.

Solution

Use the steps below to identify your storage tray based on the interface(graphical or command line) and the management software(CAM or SANtricity).

Using the CAM BUI:


   1. Open a browser to the CAM host: https://cam_server:6789
   2. Under the "Storage System Summary" area click on the array name.

  •  If the array is listed as unresponsive, you may have a communication issue.  Please correct this prior to proceeding.  Reference <Document: 1007046.1>Sun Storage 2500, 2500-M2, 6000 and Flexline Arrays: Troubleshooting Management Communication Faults.

   3. Select 'Physical Devices' and then the 'Trays' tab.
   4. Note the information in the 'Tray Type' column.
    If the tray type is a CSM100, you need to use the CLI to determine whether it is a legacy StorageTek tray type(FLA200, FLA300, or FLC200)
   5. Use the table below to determine tray type

Using the CAM sscs CLI:

   1. List managed arrays:
        sscs list array

   2. List tray information
        sscs list -d -t iom fru Tray.XX.IOM.A

  •  If the array is listed as unresponsive, you may have a communication issue.  Please correct this prior to proceeding.  Reference <Document: 1007046.1>Troubleshooting Sun StorageTek[TM], Sun StorEdge[TM], and Sun Storage[TM] Management Communication Faults with Arrays.


   3. Note the 'Model' field.
   4. Use the table below to determine tray type

Using the SANtricity GUI:

   1. Start SANtricity and Open the Array Management Window by double clicking on the array name. 

  •  If the array is listed as unresponsive, you may have a communication issue.  Please correct this prior to proceeding.  Reference <Document: 1007046.1>Troubleshooting Sun StorageTek[TM], Sun StorEdge[TM], and Sun Storage[TM] Management Communication Faults with Arrays.

   2. In the Physical window there will be a Battery/Fan Status Icon for the given tray.
   3. Look at the Product ID in that field
   4. Use the table below to determine tray type

Using SANtricity SMcli:

  1.  List available arrays:

       SMcli -d -i

  •  If the array is listed as unresponsive, you may have a communication issue.  Please correct this prior to proceeding.  Reference <Document: 1007046.1>Troubleshooting Sun StorageTek[TM], Sun StorEdge[TM], and Sun Storage[TM] Management Communication Faults with Arrays.


  2. From a command prompt, type the following:

       SMcli -n -c "show storageArray profile;"

 3.  Scroll through the output(it can be quite lengthy) and look at the TRAYS---- section.  Look for the Product ID in that field.
 4.  Use the table below to determine the Tray type

Product(SANtricity)/Model(CAM) field Tray Type IOM/ESM
Firmware
Number of Drives Drive Types
CSM100_E_S CSM100 SATA 97xx 14 SATA Only
CSM100_E_F CSM100 FC 96xx 14 FC Only
SYM2600FC FLA200 93xx 14 FC Only
SYM2610FC FLA300 96xx 14 FC Only
SYM2655FC FLC200 iSATA 97xx 14 SATA Only
SYM2655FC FLC200 dSATA 95xx 14 SATA Only
CSM200_E CSM200 98xx 16 FC, SATA, Solid State
LCSM100_E LCSM100 01xx 12 SAS or SATA
LCSM100_E LCSM100 M2 03xx 12 SAS
BladeDisk B150 B150 040x 10 blades SATA
BladeDisk B250 B250 050x 10 blades SATA



If the drive is part of the same tray as the RAID controllers, the tray type for the base tray differs by array type. 

Reference <Document:  1021066.1> Verify Sun Storage[TM] Array Array Type via the User Interface

Array ModelDrive Tray Type
2510 LCSM100
2530 LCSM100
2540 LCSM100
2530-M2 LCSM100 M2
2540-M2 LCSM100 M2
6130 CSM100 FC
6140 CSM200
6180 CSM200
Flexline 210 FLC200
Flexline 240 FLA200
D-Series D220 FLA200
D-Series D240 FLA200
B-Series B220 FLA200



Internal Comments
This document contains normalized content and is managed by the the Domain Lead
(s) of the Midrange Domain. To notify content owners of a knowledge gap
contained in this document, and/or prior to updating this document, please
add a comment to the document.



tray, type, cam, santricity, array, type, 6180, 280, 380, 240, 6130, 6140, 6540, 2500, 6000, 2510, 2530, 2540, 6580, 6780, normalized


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.