Solution  1019730.1 :   Sun SPARC(R) Enterprise M3000 and M3000-E (SPARC VII+) Server Device Paths  


Related Items
  • Sun SPARC Enterprise M3000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  

PreviouslyPublishedAs
244806


Applies to:

Sun SPARC Enterprise M3000 Server - Version All Versions and later
All Platforms

Goal

how the Sun SPARC Enterprise(R) M3000 and M3000-E (SPARC64 VII+) system device paths are arranged

Solution

Description
The intent of this document is to provide the reader with an overview of how the Sun SPARC Enterprise(R) M3000 and M3000-E (SPARC64 VII+) system device paths are arranged.

Steps to Follow - NEW


=> M3000-E (SPARC64 VII+)

|----- /pci@0,600000/pci@0 (Base Path)

                        |-- ../pci@0/scsi@0/disk0 (sd@0,0)  HD0

                        |-- ../pci@0/scsi@0/disk1 (sd@1,0)  HD1

                        |-- ../pci@0/scsi@0/disk2 (sd@2,0)  HD2

                        |-- ../pci@0/scsi@0/disk3 (sd@3,0)  HD3

                        |-- ../pci@0/scsi@0/disk4 (sd@4,0)  DVD

                        |-- ../pci@0/scsi@0/0/0/xx@5,z,     SAS port

 

                        |-- ../pci@1/network@0              BGE0

                        |-- ../pci@1/network@0,1            BGE1 

                        |-- ../pci@2/network@0              BGE2

                        |-- ../pci@2/network@0,1            BGE3

 

                        |-- ../pci@8               Slot 0 (PCIe)

 |----- /pci@1,700000/pci@0/pci@0                  Slot 1 (PCIe)

 |----- /pci@1,700000/pci@0/pci@8                  Slot 2 (PCIe)

 |----- /pci@1,700000/pci@0/pci@9                  Slot 3 (PCIe)

 

Device

Type

Device Path

IOU0 HD0

SAS/SATA

/pci@0,600000/pci@0/pci@0/scsi@0/disk@0

IOU0 HD1

SAS/SATA

/pci@0,600000/pci@0/pci@0/scsi@0/disk@1

IOU0 HD2 SAS/SATA /pci@0,600000/pci@0/pci@0/scsi@0/disk@2
IOU0 HD3 SAS/SATA /pci@0,600000/pci@0/pci@0/scsi@0/disk@3

CD/DVD

SCSI

/pci@0,600000/pci@0/pci@0/scsi@0/disk@4

SAS Port

SAS

/pci@0,600000/pci@0/pci@0/pci@0/scsi@0/0/0/xx@5,z

BGE0

10/100/1000 HDX/FDX

/pci@0,600000/pci@0/pci@1/network@0

BGE1

10/100/1000 HDX/FDX

/pci@0,600000/pci@0/pci@1/network@0,1

BGE2

10/100/1000 HDX/FDX

/pci@0,600000/pci@0/pci@2/network@0

BGE3 10/100/1000 HDX/FDX /pci@0,600000/pci@0/pci@2/network@0,1

IOU Slot 0

PCIe

/pci@0,600000/pci@0/pci@8

IOU Slot 1

PCIe

/pci@1,700000/pci@0/pci@0

IOU Slot 2

PCIe

/pci@1,700000/pci@0/pci@8

IOU Slot 3

PCIe

/pci@1,700000/pci@0/pci@9

 

IMPORTANT NOTE: CHECK following Doc to verify XCP version and patches for SPARC VII+

SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server Matrix for Hardware, Firmware and Software (Doc ID 1145383.1)



=> M3000

The following is a graphical representation of the Sun SPARC  Enterprise M3000 device path layout:

|----- /pci@0,600000/pci@0 (Base Path)

     |-- ../pci@0/scsi@0/disk0  HD0

     |-- ../pci@0/scsi@0/disk1  HD1

     |-- ../pci@0/scsi@0/disk2 HD2

     |-- ../pci@0/scsi@0/disk3  HD3

     |-- ../pci@0/scsi@0/disk4 DVD

     |-- ../pci@0/scsi@0/disk5 or 6 SAS port

     |-- ..pci@1/pci@0/network@4 BGE0

     |-- ..pci@1/pci@0/network@4,1 BGE1 

     |-- ..pci@2/pci@0/network@4 BGE2

     |-- ..pci@2/pci@0/network@4,1 BGE3

     |-- ..pci@8 Slot 0 (PCIe)

 |----- /pci@1,700000/pci@0/pci@0 Slot 1 (PCIe)

 |----- /pci@1,700000/pci@0/pci@8 Slot 2 (PCIe)

 |----- /pci@1,700000/pci@0/pci@9 Slot 3 (PCIe)

 

Device

Type

 

XSB

 

Device Path

IOU0 HD0

SAS/SATA

00-0

/pci@0,600000/pci@0/pci@0/scsi@0/disk@0

IOU0 HD1

SAS/SATA

00-0

/pci@0,600000/pci@0/pci@0/scsi@0/disk@1

IOU0 HD2 SAS/SATA

00-0

/pci@0,600000/pci@0/pci@0/scsi@0/disk@2
IOU0 HD3 SAS/SATA

00-0

/pci@0,600000/pci@0/pci@0/scsi@0/disk@3

CD/DVD

SCSI

00-0

/pci@0,600000/pci@0/pci@0/scsi@0/disk@4

SAS Port

SAS

00-0

/pci@0,600000/pci@0/pci@0/scsi@0/disk@5 or 6

BGE0

10/100/1000 HDX/FDX

00-0

/pci@0,600000/pci@0/pci@1/pci@0/network@4

BGE1

10/100/1000 HDX/FDX

00-0

 

/pci@0,600000/pci@0/pci@1/pci@0/network@4,1

BGE2

10/100/1000 HDX/FDX

00-0

/pci@0,600000/pci@0/pci@2/pci@0/network@4

BGE3 10/100/1000 HDX/FDX 00-0 /pci@0,600000/pci@0/pci@2/pci@0/network@4,1

IOU Slot 0

PCIe

00-0

/pci@0,600000/pci@0/pci@8

IOU Slot 1

PCIe

00-0

/pci@1,700000/pci@0/pci@0

IOU Slot 2

PCIe

00-0

/pci@1,700000/pci@0/pci@8

IOU Slot 3

PCIe

00-0

/pci@1,700000/pci@0/pci@9

 

For more information on Sun SPARC  Enterprise M8000/M9000 device paths, see document 1004116.1 Sun SPARC Enterprise M8000 and M9000 Device Paths. 

For more information on Sun SPARC  Enterprise M4000/M5000 device paths, see document 1002807.1 Sun SPARC Enterprise M4000 and M5000 Device Paths. 

For more information on External I/O Expansion Unit device paths, see document 1005332.1 Sun SPARC External I/O Expansion Unit Device Paths.
Note that the External I/O Expansion Unit is not supported on the M3000.

Actual device paths may be seen using some of the following methods:

OBP:   show-devs  command

Solaris:  /etc/path_to_inst  file

Solaris:   prtpicl  command

Solaris:   prtdiag -v  command

References

<NOTE:1004116.1> - Sun SPARC(R) Enterprise M8000 and M9000 Device Paths
<NOTE:1011446.1> - Sun SPARC Enterprise M4000/M5000/M8000/M9000 Servers : Logical System Board (LSB)
<NOTE:1145383.1> - SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server Matrix for Hardware, Firmware and Software
<NOTE:1002807.1> - Sun SPARC[TM] Enterprise M4000 and M5000 Server Device Paths