![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1019730.1 : Sun SPARC(R) Enterprise M3000 and M3000-E (SPARC VII+) Server Device Paths
PreviouslyPublishedAs 244806 Applies to:Sun SPARC Enterprise M3000 Server - Version All Versions and laterAll Platforms Goalhow the Sun SPARC Enterprise(R) M3000 and M3000-E (SPARC64 VII+) system device paths are arranged SolutionDescription |----- /pci@0,600000/pci@0 (Base Path) |-- ../pci@0/scsi@0/disk0 (sd@0,0) HD0 |-- ../pci@0/scsi@0/disk1 (sd@1,0) HD1 |-- ../pci@0/scsi@0/disk2 (sd@2,0) HD2 |-- ../pci@0/scsi@0/disk3 (sd@3,0) HD3 |-- ../pci@0/scsi@0/disk4 (sd@4,0) DVD |-- ../pci@0/scsi@0/0/0/xx@5,z, SAS port
|-- ../pci@1/network@0 BGE0 |-- ../pci@1/network@0,1 BGE1 |-- ../pci@2/network@0 BGE2 |-- ../pci@2/network@0,1 BGE3
|-- ../pci@8 Slot 0 (PCIe) |----- /pci@1,700000/pci@0/pci@0 Slot 1 (PCIe) |----- /pci@1,700000/pci@0/pci@8 Slot 2 (PCIe) |----- /pci@1,700000/pci@0/pci@9 Slot 3 (PCIe)
IMPORTANT NOTE: CHECK following Doc to verify XCP version and patches for SPARC VII+
The following is a graphical representation of the Sun SPARC Enterprise M3000 device path layout: |----- /pci@0,600000/pci@0 (Base Path) |-- ../pci@0/scsi@0/disk0 HD0 |-- ../pci@0/scsi@0/disk1 HD1 |-- ../pci@0/scsi@0/disk2 HD2 |-- ../pci@0/scsi@0/disk3 HD3 |-- ../pci@0/scsi@0/disk4 DVD |-- ../pci@0/scsi@0/disk5 or 6 SAS port |-- ..pci@1/pci@0/network@4 BGE0 |-- ..pci@1/pci@0/network@4,1 BGE1 |-- ..pci@2/pci@0/network@4 BGE2 |-- ..pci@2/pci@0/network@4,1 BGE3 |-- ..pci@8 Slot 0 (PCIe) |----- /pci@1,700000/pci@0/pci@0 Slot 1 (PCIe) |----- /pci@1,700000/pci@0/pci@8 Slot 2 (PCIe) |----- /pci@1,700000/pci@0/pci@9 Slot 3 (PCIe)
For more information on Sun SPARC Enterprise M8000/M9000 device paths, see document 1004116.1 Sun SPARC Enterprise M8000 and M9000 Device Paths. For more information on Sun SPARC Enterprise M4000/M5000 device paths, see document 1002807.1 Sun SPARC Enterprise M4000 and M5000 Device Paths. For more information on External I/O Expansion Unit device paths, see document 1005332.1 Sun SPARC External I/O Expansion Unit Device Paths. Actual device paths may be seen using some of the following methods: OBP: show-devs command Solaris: /etc/path_to_inst file Solaris: prtpicl command Solaris: prtdiag -v command References<NOTE:1004116.1> - Sun SPARC(R) Enterprise M8000 and M9000 Device Paths<NOTE:1011446.1> - Sun SPARC Enterprise M4000/M5000/M8000/M9000 Servers : Logical System Board (LSB) <NOTE:1145383.1> - SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server Matrix for Hardware, Firmware and Software <NOTE:1002807.1> - Sun SPARC[TM] Enterprise M4000 and M5000 Server Device Paths Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|