Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1019458.1
Update Date:2017-09-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1019458.1 :   SL8500/SL3000 - Procedure to Define SL8500 or SL3000 Alias  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  

PreviouslyPublishedAs
239865


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only

Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
All Platforms

Goal

Description
Instructions to change the SL8500 or SL3000 SDP Alias.

Solution

Oracle Confidential (INTERNAL). Do not distribute to customers

This Process works for SL3000 library also.
NOTE:
This process will continue to be valid as long as we have customers running 4.73 microcode for the SL8500 and 2.35 on the SL3000

Steps to Follow
Procedure To Define SL8500 SDP Alias:

 Contact SDP support personnel at the following numbers for assistance with installations, network/security, and technical questions/issues:

  • USA contact: +1 877-364-1940
     (supporting NA)
  • India contact: +91-80-6692-7286 or +91-80-6692-7265
     (supporting EMEA, APAC, and during off-hours, NA)
If sdpAlias is not loaded on the site server contact SDP support.
-Root password for both the SL8500 and SDP server is required for procedure. 
(SL8500 root password is only available to Level 2 Tape Hardware Support)
(contact SDP support if password is not known for SDP site server)
-If site has more than one ACS per SDP site server we need to configure an alias to re-address port_1A via the root password.
-SDP support will provide site name and site id.
-Use Motive Insight to perform device query to find site.
-Select Site Server and login via SSH.
-Login id-'stkcse'
-Password-xxxxxxx (contact SDP support if password is not known)
-At SDP menu select 7 for SDP prompt.
-Should be in the /home/stkcse directory and file named "sdpAlias" should have been copied there by sdp support.
-Secure copy file named "sdpAlias" to /usr/local/bin
  "scp sdpAlias root@10.0.11.1:/usr/local/bin"
-Enter root password at prompt; copy should complete and status presented as 100%. (SL8500 root password is only available to Level 2 Tape Hardware Support)
-Login into sl8500
 "ssh root@10.0.11.1"
-Enter root password at prompt: (SL8500 root password is only available to Level 2 Tape Hardware Support)
-Change directory to /usr/local/bin; the same directory sdpAlias was copied to.
  "cd /usr/local/bin"
-Verify no alias exist
  "sdpAlias show sl8500"
-Add alias
  "sdpAlias add sl8500 x y"
(x=2nd octet of target ip address; example 10.x.11.1)
(y=last octet of target ip address; example 10.3.11.y)
-Verify new alias.
  "sdpAlias show sl8500"
*********************************************************************************************************************************************
Example Session:
-secure copy comand syntax 
 "scp sdpAlias root@10.0.11.1:/usr/local/bin"
login as: 'stkcse'
stkcse@10.64.22.74's password:
password:xxxxxxx (contact SDP team if password is not known)
1/25/2008
* Switched driver modules for eth0 and eth1 in /etc/modules.conf on X2100
  to avoid potential forcedeth driver issue.
* This server does not have a DVD-ROM installed. Should one be needed in the
future to kickstart server, SDP Operations will need to provide one.
Main Menu
  1. Reboot site unit
  2. Check connectivity to backend
  3. SDP Processes
  4. DHCPD Menu
  5. Ethernet Interface Menu
  6. Media Management Menu
  7. Drop to Shell
  8. Clear Booster Alarms Menu
  W. Switch Menu
  R. Router Menu
  S. SANtricity Menu
  F. Floppy Configuration Commands
  Q. Exit SDP Admin
Type '7' to drop to shell
ls -l sdpAlias
-rwxrwxr-x    1 stkcse   stkcse       9699 Feb 27 14:33 sdpAlias
# scp sdpAlias root@10.0.11.1:/usr/local/bin
Password: (SL8500 root password is only available to Level 2 Tape Hardware Support)
sdpAlias             100% |*****************************|  9699       00:00
# ssh root@10.0.11.1
Password: (SL8500 root password is only available to Level 2 Tape Hardware Support)
prlibtst18:/home $
prlibtst18:/home $ cd /usr/local/bin
prlibtst18:/usr/local/bin $
prlibtst18:/usr/local/bin $
prlibtst18:/usr/local/bin $ ls -l sdp*
-rwxr-xr-x    1 root     root         9699 Feb 27 16:54 sdpAlias
prlibtst18:/usr/local/bin $ sdpAlias add sl8500 3 1
prlibtst18:/usr/local/bin $ sdpAlias show sl8500 
Type 'exit' to return to the Main menu
Type 'Q" to exit SDP Admin

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback