![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1016995.1 : Brocade - How to Get WWN of a Device from a Fibre Channel SAN Brocade Switch for HBA Binding.
PreviouslyPublishedAs 227587 Applies to:Brocade 3900 Switch - Version All Versions and laterBrocade 12000 Fabric Switch - Version All Versions and later Brocade 200E Switch - Version All Versions and later Brocade 24000 Director - Version All Versions and later Brocade 4100 Switch - Version All Versions and later All Platforms GoalHow to get World Wide Port Name (WWPN) of a device from any Brocade Fibre channel switch for HBA binding. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk/Tape Storage Area Networks
Solution
Type Pid COS PortName NodeName TTL(sec) FC4s: FCP [SEAGATE ULTRIUM06242-XXX1360]
4. Another option is to see the output of "switchshow" command, this is an example: brocade300:admin> switchshow
The WWPN of each device can be found at the end of each line (after the F-Port) ie WWN for device connected on port index 3 is 50:06:0e:80:14:39:0e:36
and STKKB5315 Attachments This solution has no attachment |
||||||||||||
|