Asset ID: |
1-71-1016366.1 |
Update Date: | 2016-03-09 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1016366.1
:
Brocade Switches: How to Get the FC Switch Port ID for HBA Binding
Related Items |
- Brocade 48000 Director
- Brocade 4100 Switch
- Brocade 5000 Switch
- Brocade DCX Backbone
|
Related Categories |
- PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
- _Old GCS Categories>Sun Microsystems>Switches>Brocade
|
PreviouslyPublishedAs
225899
Applies to:
Brocade 4100 Switch - Version Not Applicable and later
Brocade 48000 Director - Version Not Applicable and later
Brocade 5000 Switch - Version Not Applicable and later
Brocade DCX Backbone - Version Not Applicable and later
All Platforms
Goal
The goal of this document is to show how to obtain Brocade switch port ID
Solution
Step 1
Telnet into the switch/Defaults are (Username = "admin", Password = "password")
Step 2
Type "nsshow" command
Command: nsshow Example:
The Local Name Server has 1 entries [ Type Pid COS PortName NodeName TTL(sec)
N 011f00; 3;10:00:00:e0:02:21:e3:ef; 10:00:00:e0:02:01:e3:ef; na
FC4s: FCP [SEAGATE ULTRIUM06242-XXX1360]
Fabric Port Name: 20:0f:00:60:69:10:6a:c8
Step 3
The port id of the switch for the device you are binding is the PortID
Example from above:
011f00
Attachments
This solution has no attachment